Even if you reduce the branch member as you've described, there are still limits to length of weld on the branch member face such that you cannot rely on the entire branch face that is perpendicular to chord span direction. See table K5.1 of AISC 15th ed manual.
Could also check out Table K4.2...
I'll go through the links more in depth once the fabricator comes back with their ideas, but from the discussion here, it sounds like a 2" deep 1"Ø hole tapped into a 1 1/2" square block is going to be more than sufficient, especially since the block is welded between another 2-5/8" thick plates...
For concrete columns you can go as low as 0.005 * Ag (in accordance with CSA) provided you reduce your Mr and Pr accordingly. Since the Mr is largely from the steel, you might be able to do this here.
I think the reason the fab is looking to in-house it is due to lead times and increase costs to import it to Canada, and they can't find it locally. Thank you for the suggestion nonetheless.
I will look into this, appreciate the link!
The load isn't huge, but it is for a critical piece of the structure (supports a cast concrete balcony). I was going to make the tap like 2" long (1"Ø threaded rods), but if there is no real straightforward procedure to determine thread strength for standard mild steel I may have to think of a...
So to clarify, if you wanted the compression chord force at the RHS, you would take Mmax/c and NOT the sum of M1/c + Mmax/c. In your sketch above on June 11th you have F + F' = chord force, but the moment due to F is postive and F' is negative, so their top chord loads are in opposite directions...
I had a thought that ran parallel to the current discussion. I understand that OP is not talking about bracing. I had a question regarding chord force to further my understanding, in relation to chord force and lateral bracing requirements...
We are trying to come up with a detail for supporting a threaded rod in tension, and due to material availability we are going the route of tapping our own holes in a solid square stock.
I guess the square stock should be a high strength steel as opposed to 44W then? Or could I leave enough net...
Hi all,
A simple question that I have never really thought about, but if you have a bolt in tension are there any checks as far as the threads are concerned? Is there a codeified minimum number of threads (or length) to engage before getting full capacity of the bolt in tension? Is it just to...
Yes I know this thread is for shear flow, however OP has described the chord force as the shear flow. Lateral bracing requires bracing 2% of the compression chord force. So my original question is in relation to that.
This brings up an interesting thought in my head. When bracing a cantilever beam going into negative bending at the support (to decrease Lu) we typically size it for 2% of the factored compressive load at the brace point, which we have been determining as negative moment / depth of beam. If F...