Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. yhisus

    Windshield design for outdoor equipment

    Hi all guys. Our customer doesn't think about any building, thus. the equipment is located outdoor due to general specifications. If you don't know how to design a windshield, it's ok, but not try to change the real meaning thread. Thank you for the proposals, but they are not suitables for...
  2. yhisus

    Windshield design for outdoor equipment

    Sorry, this is the real link.http://www.simu-therm.net/images/stories/big_air_flow_sample_2.jpg
  3. yhisus

    Windshield design for outdoor equipment

    I'm attaching the next image corresponding with the link I've posted beforehttp://www.simu-therm.net/index2.php?option=com_jce&task=popup
  4. yhisus

    Windshield design for outdoor equipment

    Hi willard3. I mistook the equipment. It's a steam superheater, it's true it must be installed outdoor and probably alone, only connected by piping (inlets, outlets). If you can, please, visit this addresse and you will understand what I mean...
  5. yhisus

    Windshield design for outdoor equipment

    Thank you macmet. We are seeking how to build a wind/rainshield because our equipment is a waste heat boiler. As you can consider, it's no use to put up a bulding. In winter we'd have no problems but in summer, there would be any refrigeration of the system and we should think about placing an...
  6. yhisus

    Windshield design for outdoor equipment

    Hi all guys, I have a problem with the thermal design of a waste heat boiler. The equipment will be installed outdoor and the difference between the winter (-25ºC or -13ºF) and summer (40ºC or 104ºF) temperature is a great problem. My colleagues and me, we are together thinking about something...
  7. yhisus

    Biogas Burner - Air/Fuel Ratio

    Hi all. I'm planning to evaluate the likely installation of a burner to warmp up process air for a spray dryer. At the customer facilities there is a landfill and we will use the produced biogas as a feed for the burner. Regarding the biogas burning environmentally, we have to burn it...
  8. yhisus

    Spray Dryer Design

    Hi everybody!! Has anyone the Spray Dryer Handbook by K. Masters in pdf format that Latexman recommended me? Thanks.
  9. yhisus

    Spray Dryer Design

    Thank you micalbrch & Latexman. I tried to buy The Spray Dryer Handbook but in Spain its impossible. I will talk with my lecturer in order to get it. Bye.
  10. yhisus

    Spray Dryer Design

    Hi all!!! I'm in the early times of designing a spray dryer but I don't find any info about how to design it. Can anybody help me with this problem? Has anybody some info or handbook about it? Thanks all in advance.
  11. yhisus

    Sizing High pressure Oil-Water separator

    Thanks Aggie87, I will take a look on this. bye,
  12. yhisus

    Selecting materials for piping systems

    Thomasjl, try getting ASME B31.X (where X are natural numbers). All these codes will give you some information about several piping systems and how to design it. I hope this post serves you to begining your search.
  13. yhisus

    Sizing High pressure Oil-Water separator

    Hi all, can anybody give me some information about designing (sizing) high pressure separator for high pressure oil-water streams? There is a pressure of 350 barg. Can anybody help me to design this equipment? The API 421 standard doesn´t apply for this design because the separator must be...
  14. yhisus

    Corrosion Rate of AISI 304L Stainless Steel with Methanol

    Hi all, I'm looking for a corrosion chart or table where corrosion rate of AISI 304L in Methanol (Methylic Alcohol)is analised. I have to design the piping of methanol transport and i would like to know the anual corrosion rate for methanol at, at least, 130ºC, 2,5 bar (absolute). Thank you
  15. yhisus

    Corrosion Rate of AISI 304L Stainless Steel with Methanol

    Hi, I'm looking for a corrosion chart or table where corrosion rate of AISI 304L in Methanol (Methylic Alcohol)is analised. I have to design the piping of methanol transport and i would like to know the anual corrosion rate for methanol at, at least, 130ºC, 2,5 bar (absolute). Thank you

Part and Inventory Search