Recent content by pipe78

  1. pipe78

    CCTV & Sonar

    Thank you, cvg. Do you know how to qualify the CCTV/Sonar tape or where I can find this information?
  2. pipe78

    CCTV & Sonar

    For existing CSO pipe cleaning project, how much per foot include CCTV / Sonar inspection and cleaning. Pipe diameter is between 18" to 84". Thanks.
  3. pipe78

    CCTV & Sonar

    Does anybody know where I can find the CCTV & Sonar evaluation information?
  4. pipe78

    customised line types

    1. Open acad.lin file. 2. Copy the existing file example and past it at the end of the page. 3. Modify it to what you want. Tip: The better to keep the standard default setting.
  5. pipe78

    ACAD2000 paperspace Dimensions

    1. In model: Create drawing in 1:1 2. In layout: a) Create viewport and set up scale what you want b) in model space: use "z" c) in paper space: use "mvsetup" Note: pay attention about your dimension and text height. Good luck.
  6. pipe78

    Dimension movement

    I think the point that you selected when you do stretch is the same as your dimension point. I mean you selected your dimension!!
  7. pipe78

    How to connect new DIP to existing RCP?

    CVG: Thank you very much about the technical resource. I'll use this in other projects, because it is combined sewer pipe this time. lha(Steve): Thanks for your response. I am insteresting this word because I know Chinese.
  8. pipe78

    How to connect new DIP to existing RCP?

    semo: Thank you. I can't use concrete junction box, because budget. lha(Steve): You are right. That's why I am thinking about Steel Coupling Reducing: www.smith-blair.com. By the way, why do you give a "Remember"? You know Chinese? cvg: Thanks a lot. I don't know if the reinforced concrete...
  9. pipe78

    How to connect new DIP to existing RCP?

    Connect new 36" Ductile Iron Pipe to existing 36" Reinforce Concrete Pipe. How can I do? Can I use Steel Couplings Reducing? Thanks.
  10. pipe78

    [b]How to Repair 102 Years Heavy Corrosion Pipe[/b]

    No, I can't. Because: 1. There are enough capacity 2. Don't need change all of them 3. Too much more money
  11. pipe78

    [b]How to Repair 102 Years Heavy Corrosion Pipe[/b]

    Thanks cvg[smile]. The pipe is working now. I can't drain the reservoir to replace the pipe[surprise][sad]. There is a gate valve in middle of the pipe. The gate shaft is on top of the dam. There is another valve nearby the outlet. We need repair the pipe that is between these two valves. I...
  12. pipe78

    [b]How to Repair 102 Years Heavy Corrosion Pipe[/b]

    In this project, there is a 48" dia. 124 LF pipe(include pipe reducer from 48" to 36" for gate valve installation) which is under a dam about 100' and has 102 years. In the report:"...The overall condition of the pipe is fair due to heavy corrosion of the steel pipes and rivets with moderate...
  13. pipe78

    Coating for pipe interior

    Thanks for your reply Metalguy. The pipe is old smooth steel pipe and the dia. is 48". No saltwater.
  14. pipe78

    Coating for pipe interior

    What kind of coating system is better for the steel pipe interior painting? The pipe is under the DAM about 100 ft and the water resource is protected.[ponder] Thanks a lot for your help. [smile2]
  15. pipe78

    casing pipe design and spec

    cvg, thanks a lot to give me a good reminder.