A plate in contact with the back side of the Electrode (the metal part) is applying the sealing force by tightening 4 bolts.
The o-ring does not damage after the test.
the gland dimensions: Inner Diameter: 2mm, Outer Diameter: 6mm, Depth: 0.9mm
the o-ring dimensions: Inner Diameter: 3mm, Outer...