  1. scorcher

    Tray Damage Detection

    Hey, Does this type of scan work for packed columns?? Thanks
  2. scorcher

    Phenol Destruction

    Phenols are easily digested in a standard bio plant to 0 levels. They are easily digested at these concentrations
  3. scorcher

    Recovery of acid tower packings

    Hi, I am looking for an efficient way to re-use packings form a tower contining 98% H2SO4. Removal of old packings is by vacuum, while replacing them must be carried out by hand. TO avoid handling acid comtaminated packings, we dispose of teh old packings and replace with new ones. Does...
  4. scorcher

    H2SO4 level instrument

    Gents, Thanks for the advice. Radar was my first choice, but although they are the gauge of choice at our site too, we have seen problems with un-even surfaces (tank volume turned over 5-10 times per hour in this case) Stilling wells are the obvious answer, but surface scale and corrosion...
  5. scorcher

    Jet Fuel Bulk Storage

    Hi, Jet engines are a long way from my line of work, but this similar thread thread995-85538 might be relevent. You stated the problems with brand new engines. Perhaps the problem is to do with a change in the cleaning regime (even seasonal changes here) I know this is off the stratification...
  6. scorcher

    H2SO4 level instrument

    Hi, I am looking for are replacement level instrument for 96-98% H2SO4 in a tank with high turn-over and water addition. The current air bubblers (used for indication) tend to fail regularly due to the tubes blocking with corrosion products. THe new isntruments are part of a control system and...
  7. scorcher

    PH measurement

    We are trying to use conductivity in preference to pH measurement (approx 13pH). However, process fluctuations are resulting in conflicting results and poor control. Conductivity is maintained well, but corresponding pH less so. Lab trials had not given any sigh of this issue. Conductivity...
  8. scorcher

    How acid is formed in dry 14% SO2 gas line ?

    6748, I know of a similar plant which generates SO2 (and acid as a byproduct). From talking to people at the plant I have learned 2 things. 1. They use liquid sulfur, stored above 135C but still "expect" to have some moisture in their sulphur.(the tank is open vented, I am not sure if they...
  9. scorcher

    How acid is formed in dry 14% SO2 gas line ?

    6748, I know of a similar plant which generates SO2 (and acid as a byproduct). From talking to people at the plant I have learned 2 things. 1. They use liquid sulfur, stored above 135C but still "expect" to have some moisture in their sulphur.(the tank is open vented, I am not sure if they...
  10. scorcher

    PVDF Hot conc sulfuric acid

    All, Thanks for all the help. We have trialed modified tee (PVDF wiht steel support). Early indications seem encouraging. We will be upgrading the other strength meters following a longer successful trial. Regards
  11. scorcher

    program for conversion?

    http://www.processassociates.com/process/convert/cf_all.htm
  12. scorcher

    PVDF Hot conc sulfuric acid

    Moltenmetal, To elaborate, the equipment is an instrument tee (sound velocity/acid conc). Exposure to acid is constant, conc constant to +/- 1%, operating temp in range 50 to 80C. Instrument is installed in a 1" branch off a process tank circulation line, pressure up to 4 barg, so...
  13. scorcher

    PVDF Hot conc sulfuric acid

    Hi, I am trying to source information on the suitability of PVDF (piping) with hot (up to 100C) 90-98.5 sulphuric acid. Information I have found so far gives the full range of "suitable" to "not suitable". I know that the temperature itself is OK, but am looking for clarity...
  14. scorcher

    Ullage/sizing

    Is there a consistent definition of ullage? E.g., if a tank is quoted as 100m3, is this the absolute volume, the mechanical design volume to a level, or the maximum liquid in normal operation. Which of these figures does ullage relate to. Similarly for reactors, if it is quoted as 10,000l...
  15. scorcher

    Sulfonic acid handling

    This is what we use on site for TSA. NICKEL-COPPER ALLOY (MONEL 400) SEAMLESS ANNEALED PIPE MADE TO ASTM B 165. N04400 (N1/CU) SCH40S or ASTM F423 (PTFE) OUTER API gr.B SC40. LINNER ASTM D1457 TYPE I If you are still interested, I can check what we use on our PTSA plant? Perhaps you could...
  16. scorcher

    Demisters

    Our plant burns liquid sulphur to produce SO2 to be fed directally to another plant on site. The SO2 is cooled initially in a waste heat boiler, then further cooled to around 160C as the transfer pipe supplies it to a final packed tower. This tower contacts the gas stream with 98% acid to...
  17. scorcher

    Static Mixer Sizing and Design

    TAD123, Ive found Sulzer chemtech to be v helpful in the past. Their Sulzer mizer seems to be a by-work for static mizers in ant searches I've done. I know this is a bit of a cheat, but let the experts do their stuff. Scorcher www.sulzerchemtech.com
  18. scorcher

    Static Mixer Sizing and Design

    TAD123, Ive found Sulzer chemtech to be v helpful in the past. Their Sulzer mizer seems to be a by-work for static mizers in ant searches I've done. I know this is a bit of a cheat, btu let the experts do their stuff. Scorcher www.sulzerchemtech.com
  19. scorcher

    H2SO4 Plant pumps

    All, I need to source some new pumps used to pump liquid sulphur at 130 - 145C. Can you suggest any specialist suppliers for this type of equipment. Also, 96 to 99% H2SO4 at temps up to 90C. Are submerged pumps the best way to handle these types materials. I have found Lewis pumps, are ther...
  20. scorcher

    Chemical feed of NaOH

    I am lookig at a similar problem with caustic flow (25%). For reliability (not accuracy) reasons, it has been decided to change from a turbine to a mag flow system. For processing reasons, the concentration can decrease significantly from its design value, as the caustic changes to other...