  1. urjaengrs

    What is double wond transformer

    Thanks scotty, Why normally this term is used for isolation transformer? Is there any constructional difference netween normal distribution transformer and isolation transformer? Thanks in anticipation of replies
  2. urjaengrs

    What is double wond transformer

    Please let me know the difference between double wounfd and single wound transformer? In anticipation, thanks...
  3. urjaengrs

    DC resistance of cable

    All manufacturers mention value of DC resistances for their cables. We normally use ac resistance for calculation purpose. What is nescessitiy of mentiong DC resistance then? Is it only for confirmation to limitation of resistances to standard? Please help me out. In advance, thanks....
  4. urjaengrs

    Standard Cable Sizes

    I would like to know regarding standard cable size. Who defines it, i mean which standar has defined this. Is somebody is aware why the standard concluded for a particular size. For exampl, why cable size is of 70 sq.mm. only and not 75 sq.mm. In advanse thanks..........
  5. urjaengrs

    Voltage rating of bus duct insulators

    Dear Friends, Still I am bit confused regarding rating of insulators. Normally, why bus duct support insulators are up-rated that switchboard insulators? Please answer............ Thanks in anticipation
  6. urjaengrs

    Voltage rating of bus duct insulators

    I have observed one thing regarding insulators of LV busduct in one project. For low voltage busduct connecting transformer and switchboard, I have observed that the voltage rating of insulators is 3.3kV. Why these insulators are up-rated? Can anybody help me? In advance, Thanks.
  7. urjaengrs

    Starting power factor of motor

    Thank you all. Actually, I need this starting power factor for motor study calculations. If somebody provide me typical starting power factors for all range of motors, it will be highly appreciable. In advanse, thank you very much..
  8. urjaengrs

    Starting power factor of motor

    I have one question regarding motor power factor. I need to calculate the voltage drop in cable at starting of motor. How to calculate motor starting power factor of motor? Does any motor manufacturer mention it? IS there any relationship with running power factor. Please help me out. In...
  9. urjaengrs

    Short circuit withstanding capacity of LV cables

    I do have one question in my mind. while going through the specifications for cables i do not find short circuit withstand capacity mentioned in case of LV cables. But these are clearly specified in HV or MV cables. My question is why there is no much importance to withstand capacity in case...
  10. urjaengrs

    connection of dual core current transformer

    Thanks all.. there was typographical error. For S1 & S3 ratio is 400/1 and between S2 & s3 ratio is 200/1. however, still the question remains un-answered. Why unused terminal to be left open.. I hope i will get the answer
  11. urjaengrs

    connection of dual core current transformer

    Thanks to all the memeber who had given their opinion. however, still I am not convinced. Can somebody therotically answer my query? can anyone have literature on the multitap CT secondary connection subject?
  12. urjaengrs

    Rating of DG sets

    I have observed that normally, low voltage DG sets ratings mentione din kVA and high voltgae DG sets in MW. Can somebody put his input regarding DG sets ratings. Is there any standard for mentioning these ratings? Whether it shall be mentioned in MW ort in MVA? I do agree that all electrical...
  13. urjaengrs

    VFD rating

    Can anybody guide me regarding rating of VFD? how it is co-related to motor kW rating? Is it nescessary to de-rate VFD i.e. if motor kW is 90 kW, then VFD rating should be 110 kW. is it so? Also, what other factors to be considered for determination of VFD rating as well as motor kW rating...
  14. urjaengrs

    VFD Motor Earthing

    Can somebody explain the earthing of VFD fed motors? Is normal motor body earthing is sufficient? Is earth falut curren flow back to main power supply when winding of motor gets earthed? I am asking this question as there is VFD in between main power source and motor i.e. there is conversion of...
  15. urjaengrs

    connection of dual core current transformer

    Thanks Raghunath.. it is single core CT only. Can you any backup document which will support your answer. Because I am also of the same opinion but not getting any backup. Please provide if u have.. Once agin thanks a lot...
  16. urjaengrs

    MV switchgear - bottom cable working clearance

    i think the clerence you cinsidered is fare enough.. if it is 1200 mm or more that wud b better. ofcourse, as suggested by JMOUNCE, please refe some guidelines baout bending requirements of HV cable
  17. urjaengrs

    connection of dual core current transformer

    i would like to know the information about current trasformer. I have dual core current transformer with three terminals viz s1, s2 and s3. s1 is common and earthed. Between s1 and s2 i get ratio of 200/1 and between s2 and s3 i get ratio of 400/1. if i would like to use s1 and s2 with ratio of...