  1. arguellesmanuel

    Vertical Fire Tube Boiler

    You must first consider the demand required steam, then you can estimate the size of the boiler.It is important to know that maintaining a vertical boiler is a bit more complex than the horizontal type. http://www.hurstboiler.com/documents/184/vix_series.pdf regards, MA
  2. arguellesmanuel

    Pseudomones in sand filter

    Hi, I have problems with a sand filter / zeolite. change the filter bed two months ago and since then the filter has to count out pseudomonas aeruginosa. try soaking the bed with a solution of calcium hypochlorite and we are waiting for microbiological results. if not improve water quality need...
  3. arguellesmanuel

    Lower the Silt Density Index before RO filters

    It is important to know the values ??obtained from SDI, however, it is important to know that the filtration process is nearly always the most appropriate, as long as the design is in tune with the consumption of water per day. If your water usage is very high compared to the specifications of...
  4. arguellesmanuel

    Unlike CEDI variables

    Good morning, I have a purified water plant where the final two drives in parallel CEDI which serve to bring the conductivity of 2.5 microsiemens approximately 0.300. I would like to know why there is a difference of amperage on both drives, is this normal? yesterday conducted a chemical...
  5. arguellesmanuel

    Unlike amperage CEDI units

    Good morning, I have a purified water plant where the final two drives in parallel CEDI which serve to bring the conductivity of 2.5 microsiemens approximately 0.300. I would like to know why there is a difference of amperage on both drives, is this normal? yesterday conducted a chemical...
  6. arguellesmanuel

    Salt quality for softening system??

    ok thank you very much, my doubt was cleared. Manuel Arguelles Pharmaceutical Plant
  7. arguellesmanuel

    Salt quality for softening system??

    Good day, I know the reason why I can not use in my system Softening industrial salt with iodine and fluoride? Currently it is difficult to get into this salt market and in my store there is only edible salt with iodine and fluorine. I have two days softening salt for human consumption...
  8. arguellesmanuel

    pH meter problem..help me.

    Hi, Placed in KCl solution to prevent wear on the electrode, once you have calibrated your Phmeter should have no problems. - Check the temperature of the samples meet the specifications of the electrode. - Check your calibration buffers are correct. (normally used calibrated between 4 and 7) -...
  9. arguellesmanuel

    Which one is better Bromine or Calcium Hypochlorite

    Hello, from the standpoint of efficiency, you should consider that as a function of pH hypochlorite is effective at pH 6 -7. What I see is that you can have long-term scaling problems due to the form of calcium. If you can use sodium hypochlorite would be excellent. Greetings. Manuel...
  10. arguellesmanuel

    Concentration of the condensed sulphuric acid

    hello, for a mixture of several species (SO2, H2O, CO2, O2) is very difficult to predict behavior. Raoult's law holds for mixtures of two species in a vapor-liquid diagram for your case, taking into account the two higher molecular weight species (SO2 and CO2) and apply the diagram McCabe...
  11. arguellesmanuel

    Re- passivation 316L ss demi water loop

    Hi, usually the SS is affected by high concentrations of chloride. Anyway, put a 1 micron filter in the loop and replace it when you have a drop of 5 psi. This will help with the erosion in the pipe (if any). Additionally I would like to know the system volume and the amount of chloride...
  12. arguellesmanuel

    Ion Exchange Backwash in a WWTP

    You should check the volumes of waste vs. the final volume to download, and also review the chloride discharge limits in your area. Usually biological systems are limited in the removal of high amounts of chlorides. M.Argüelles
  13. arguellesmanuel

    phosphates in the cooling water. future problems??

    Hi, I have a cooling system (evaporative condenser) with the following conditions: 1. The makeup water containing 2 ppm of ortophosphates. (Used as corrosion inhibitor in the pipeline). 2. This water is used to feed a cooling system which uses an alkaline dispersant based on phosphonates...
  14. arguellesmanuel

    pH effluent in Secuencial Batch Reactor

    Thanks, and the white foam in the aereation phase?? Manuel Arguelles Venezuela
  15. arguellesmanuel

    pH effluent in Secuencial Batch Reactor

    Hi, i have problems in my wastewater plant: The pH of effluent is near to 8.0, the pH feed to SBR is near to 6.5 and in the reaction phase have much white foam. it is possible that the foam must to an excess of coagulant/floculant used in unit CAF, previos to SBR. Water Analysis are: Feed...
  16. arguellesmanuel

    Silica Solubility

    Hi, Betz dearborn have a paper related with a operative consensus in the chemical water of boiler water suggested by the ASME. http://catalog.asme.org/books/CDROM/Consensus_Documents_Feedwater.cfm Request me in any time. Manuel Argüelles Quality Analist Venezuela
  17. arguellesmanuel

    Feed boiler corrosion

    what is the ideal pH for a feedwater boiler to work 150psig? * The pH feed is behind 6.8 and 7.5 but in the boiler have pH 11 at 3 cycles. I can have problems in the future?? I feedind NaOH and my feed pH raise 9.2, but is not very high?? sulfites residuals is 30-60 ppm. Thanks. Manuel...
  18. arguellesmanuel

    concnetration

    you are determine phosphate with NaOH? dont understand?? 1. Said me the type of kit that you are using?? 2. if the stequiometric relation behind NaoH and Phosphate is = 1. ppm PHOSP= ml NaOH added*Conc of NaOH* PMolecular of PHOSP/Sample volume. Bye. CHEM. TeCh Manuel Arguelles Quality...
  19. arguellesmanuel

    Pumping hard water

    Not only the hard water can bring any problem in the impeller...silice too..!! the temperature have a importan factor... what is the amount of silice that you have.?? use a bypass use a softener.. o use a dispersant in a cocentration of 10-15 ppm. (poliacrilate or poliacrilamide) Chem. Tech...
  20. arguellesmanuel

    Effluent treatment papers or www.

    Hi, I need to find papers or web pages related with effluent treatment, information such as Treatment theory, SBR, DBO, unitary operations, interpretation of water analysis for waste water. philosophy of plant operator and wastewater laboratory. im beginning a new job related with this, and my...