  • Users: DG72
  • Order by date
  1. DG72

    STHE minimum radius for bend part of U tubes.

    Generally, for most materials, a bend diameter 3 X tube o.d. is acceptable. As stated above, you will need to compute minimum tube thickness per ASME and apply TEMA rules to calculate thinning at u-bends. Beyond TEMA and ASME, you should contact tube supplier. Some materials present different...
  2. DG72

    tube to tubesheet joint for U type heat exchanger

    FYI--You might check the material specification for SA-105. It states that it is not intended for tubesheet material.
  3. DG72

    OSHA Requirement for Proof Testing of Lifting Lugs

    Bump...I am anxiously awaiting someone smarter than me to respond.
  4. DG72

    Flange machining

    I think the key word there is "bar".
  5. DG72

    ASME Sect. 1 sequence of RT and PWHT completion

    I agree. Unless the customer specifies otherwise, our standarad practice is to perform RT prior to PWHT. Of course, many require us to RT after, in which case, we perform RT before and after.
  6. DG72

    Meaning of TST on Boiler Datasheets

    Tube Side Temperature?
  7. DG72

    CS Tubesheet, 304 Tubes, 500degF

    You will likely want to weld the tubes to the tubesheet. It is difficult to get a tight seal with this combination of metallurgies when roller expanding only. It takes a lot of force to expand stainless steel tubes, and this often moves (yields) the carbon steel ligament between the tube...
  8. DG72

    PE Status for PVs

    PE's are nice, but irrelevant to the issue at hand. Hire competent personnel and you will do great. The Botanist example is an unfair argument. (You went from one extreme to the other.) I know many shops that have non-degreed personnel and they do okay, but I require engineers with degrees...
  9. DG72

    PE Status for PVs

    "Wow, no PE sign off for Div1 in the USA?? Is this regardless of pressure and contents? So you don't have to get designs verified at all? Sounds dangerous to me." What's dangerous about that? I don't remember there being anything pertinent to Div. 1 on PE exam.
  10. DG72

    General Inspection Procedure

    We have a baseline ITP that we use as a minimum--customer requirements are added to it. Do you have something similar?
  11. DG72

    Tube Sheet Crack

    I don't believe that UT is feasible, since the tubesheet is perforated. Regarding a repair, you will likely be chasing cracks all day. About the time you think you have found the bottom of the crack, it spider webs to a larger mess of cracks. Hopefully, your schedule will allow replacement.
  12. DG72

    EM12K procedure

    Vesselfab, I usually agree with your posts. In this case, let me explain our position. A few years back, our WPS was rejected by our client on the basis that the wire/flux combination wasn't certified by the mfg in the PWHT condition. This came as a shock to us since we had easily qualified...
  13. DG72

    EM12K procedure

    As long as you successfully qualify the wire/flux combination per ASME section IX, it is legal per ASME. The problem is, the welding consumable mfg's do not "certify" the wire/flux combination in the PWHT'd condition. This shouldn't matter, since ASME doesn't require this certification, but...
  14. DG72

    U1 With Violations

    What's the error? The exchanger could have been built exactly to spec and an error was made on the U1. Typically, the U1 should be sent back to the original fabricator for correction. A corrected copy is generated with the change signed by the A.I.
  15. DG72

    100% RT Vs. Full RT

    While I agree that code doesn't define 100% RT, I don't consider 100% to be ambiguous--it means all; no code exemptions for small nozzles (it's okay to go above and beyond code minimums). I agree with vesselfab. Whether code recognizes the term, or not, doesn't matter. As long as you are...
  16. DG72

    WPS with Impact Testing

    Since some people don't fabricate, they get paid to argue and argue--that is the product they sell their client.
  17. DG72

    channel to shell gasket type at BEU HEX

    B16.5 flanges (raised face) are fine as long as the gasket has the outer ring. TEMA requires a confined joint.
  18. DG72

    TEMA R : confined gasket

    See the TEMA interpretation below. TEMA inquiry # RCB 6.5 (312): "Will any gasket type which includes an outer metal retaining ring meet the requirements of a "confined gasket" between two raised face flanges, or must the gasket be spiral wound type? For example, would Kammprofile Style ZA or...
  19. DG72

    Quenching Stainless Steel Welds

    Cracks due to thermal expansion/contraction as the weld cools?