    Agitator Nozzle Flange Face Roughness Requirements

    Hello, We are planning to install an agitator in the bottom head of the vessel. My question: are there any specific requirements to the roughness (AARH) of the face of the flange connected to the mounting flange of the agitator?
  2. nur12

    Professional Liability Insurance

    I am a mechanical P.Eng. I am just starting to work as a contractor for an engineering consultant company. My contract with the Company states that I am responsible for buying liability insurance. Could anybody tell me how much a typical annual premium for professional liability insurance and...
  3. nur12

    Question about your (life) partner

    Have you noticed how many engineers are married to nurses? In every company I've every worked for there are always a few, A FEW. Actually, I can not think about any other occupations which follow the same pattern.. I am always puzzled by questions: why engineers and nurses? how do they actually...
  4. nur12

    Saddles "MDMT"?

    Hello, Is it correct to use the acronim "MDMT" if talking about vessesl saddles? Fo rexample, if the vessel saddles to be exposed to -50 deg C, shall I mention MDMT or MMT (minimum metal temperature)= -50C? I was under the impression that "MDMT" applied only to pressure envelope. Thanks.
  5. nur12

    ASME Code Case 2211

    This is great, thanks a lot!
  6. nur12

    ASME Code Case 2211

    lostsailor, So, if the code case 2211 was approved - as metengr mentioned -in 1999, it supposed to be included in 2004 Ed. of Code, but it is not there. Could you please suggest where else I might be able to find it? Thanks.
  7. nur12

    ASME Code Case 2211

    Thanks metengr!
  8. nur12

    ASME Code Case 2211

    Hello, I can not find in our library any reference to ASME Code Case 2211 "Pressure Vessels with Overpressure Protection by System Design". Is this a separate document or it is a part of the Code? Thank you.
  9. nur12

    Where would you like to be?

    I would live only in San Francisco. Nothing can compete to this. Yes, it is expensive, but the life surrounded by SF beauty and spirit worth everything.
  10. nur12

    ASME Section VIII Div. 2 - Full Range Pr. Cycle Definition

    Hi, What is "full-range pressure cycle"? Thanks.
  11. nur12

    Vessel vs. Column - Ratio?

    Hi, I have a simple question - from which length / diameter (or diameter / length) ratio the vertical vessel is considered a tower (column)? I have a Pressure Vessel handbook, but there is no information about this particular question. Thanks!
  12. nur12

    Hydrotest Pressure on Vessel Nameplate

    Hi, In our project specification we've asked the Vendor to hydrotest vessel to 1.3 MAWP (new& cold). I've got a question from them - which hydrotest pressure shall be mentioned on the vessel nameplate, 1.3 x MAP new&cold or 1.3 MAWP (the pressure of the test done at the field)? Their concern...
  13. nur12

    Flare Stack Flame Monitoring Options

    Thanks, bmoorthy, I've read this standard. I'm interested more in practical side of the issue.
  14. nur12

    Flare Stack Aircraft Warning Lights Requirements

    Thank you very much, it is exactly what I need!
  15. nur12

    Flare Stack Aircraft Warning Lights Requirements

    Thanks, I've already checked John Zink website and didn't find any reference to the required matter.
  16. nur12

    Flare Stack Aircraft Warning Lights Requirements

    Hi, I'm evaluating the flare stack bid proposal. The flare is 37 m high. One Vendor had included in the quote the aircraft warning lights, but the other one did not - he had mentioned that per ICAO recommendations, it is not needed for the flare of this height. The question: is ICAO the only...
  17. nur12

    Flare Stack Flame Monitoring Options

    Hi, I'm doing a bid evaluation for flare stack and try to evaluate the options for pilot flame monitoring: thermocouples, UV or infrared monitors, ot acoustic monitors. Do you have expierence with any of this? What is your favorite? Why? Thanks.
  18. nur12

    How many manways per vessel?

    Thank you, it helps a lot. Unclesyd, that's funny.
  19. nur12

    How many manways per vessel?

    Hi, I can't find any info in the Code regarding correlation between vessel length and quantity of the manways required. Is there anything (except common sense) to justify how many manways shall be on the long vessel (9 m and up)? Thank you.
  20. nur12

    Radiography before/after PWHT

    http://www.eng-tips.com/viewthread.cfm?SQID=83340&SPID=404&newpid=404&page=1 You may find this thread helpful. Regards.