Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. pvesseleng

    Checker

    I mean, I heard that after all formal procedures, inspection and testing and examination. one person assigned as "Checker" who has no technical backround. Just he is questioning like: "Why this is here?" Is it necessary? How its working? etc."
  2. pvesseleng

    Checker

    Hi, Is there any body has information about "the checker person" in nuclear power plants?
  3. pvesseleng

    DIN17155 is replaced with which standart for pipes?

    DIN17155 is replaced with which standart for pipes? ulyssess (Materials) 11 Jun 08 write For plates: 15Mo3 was the designation in DIN 17155, replaced in 1993 by EN 10028-2. At the same time, the name was changed to 16Mo3, maintaining the steel number 1.5415.
  4. pvesseleng

    Welding Consumable Shelf Life

    Is there any shelf life for welding consumable (excluding electrodes)? Thanks
  5. pvesseleng

    Is this considered pressure part?

    In relation to the geometry pressure containing parts the scope of Section VIII Div.1 ends with the face of first flange for bolted, flanged connections. Please see U-1(e)(1)(c) of SC VIII Div.1 I would consider as follows; Gasket is out of the scope, It is not required to have U stamp for the...
  6. pvesseleng

    Manufacturer's Design Report / WPS-PQR's

    No, there is no need. AI must review welding documents thats all.
  7. pvesseleng

    BPVC U Design & Fabrication Uniformity

    No but overall responsinsibility is belong to certificate holder
  8. pvesseleng

    Dublex wire penetrameters

    Hi, ASME SC V Article 2, T-276.1 references SE-747 for wire type penetrameters, but SE-747 does not include dublex wire type penetrameters. Does it mean that dublex wire type penetrameters is not permitted? Best Regards
  9. pvesseleng

    Fig.UCS-66 (g)(3) Normalized rolling condition

    Lets assume the item is formed at normalizing temp. and then held there for a time after forming. Results; time and temperature recorded on material test report. Is this the same situation explained in ASME Section VIII Div.1 Fig.UCS-66 (g)(3)? thank you for your valuable comments
  10. pvesseleng

    Fig.UCS-66 (g)(3) Normalized rolling condition

    Hi, ASME Section VIII Div.1 Fig.UCS-66 (g)(3) states that "Normalized rolling condition is not considered as being equivalent to normalizing" Does it mean that if heads formed in normalizing temperature, can not be assumed as normalized. Regards
  11. pvesseleng

    Referencing Different Editions of the Same Book

    Hi, You can not use latest or another edition which are not referenced on your construction code edition.
  12. pvesseleng

    Edition and Addenda

    Actually, I meant to say the following: We have used a supplier to manufacture one part of our pressure vessel. The supplier constructed the U PART stamped item as per ASME Section VIII Div. 1 2004 Edition 2005 Addenda however the pressure vessel is in accordance with ASME Section VIII Div. 1...
  13. pvesseleng

    Edition and Addenda

    Is permitted to use U part item constructed in accordance with ASME Section VIII Div.1 2004 Edition 2005 Addenda on to be U stamped item consructed in ccordance with ASME Section VIII Div.1 2004 Edition No addenda. If yes please give code reference or interpretations. Thank you.
  14. pvesseleng

    Buttering

    3lilaggies, If you are using FCAW method, I would really recommend you for prevention of crack as metengr mentioned
  15. pvesseleng

    ASME SC VIII Div.1 UW-17(f)(1)

    yes I meant -40°C MDMT. sorry for bad question. Thanks
  16. pvesseleng

    ASME SC VIII Div.1 UW-17(f)(1)

    Yes I meant UW-37 (f). Thank you.
  17. pvesseleng

    ASME SC VIII Div.1 UW-17(f)(1)

    Is it the intent of ASME SC VIII Div.1 UW-17(f)(1) welder stamp can not be applied at -40ºC for ferrous materials.
  18. pvesseleng

    Tack welders

    Tack welder has to be certified as per SC VIII Div.1, Div2, and SC I.
  19. pvesseleng

    Nameplate units

    There is no need code case the important matter what is the edition and addenda to be used in construction? If the equipment in accordance with latest code edition and addenda; You can write.