  1. zoo123

    power factor issue

    Dear friends, my sincere thanks to you all for the reply and input advices you provide. thank you. I want to indicate to you that the Govt utility( power company) people, inspect and specifically look for a capacitor bank avaialbility prior to approving the connection. While, that said, how...
  2. zoo123

    power factor issue

    meanwhile not sure what u meant by POCC. aLSO, It would be good to know if the capacitor can be kept on always or how it has to be connected. can you throw some lights. thanks though
  3. zoo123

    power factor issue

    thanks for your inputs. but at the end of the day, the Govt people keep penalising my small start up intentions and heavy penalty levied on me. The power factor of 0.1 , means i utilise a current on a average of 5 to 8 amps, but with the VAR, iT SEEMS they pump in 150 amps. so, how i effectivly...
  4. zoo123

    power factor issue

    power factor issue at my shed , seek advice? dear friends, i have a commercial power line taken from Govt owned lines, as is usual. with my new start up, i registered for a min. use of 4kw and connections provided in 2021. I changed the same to permanent conneciton in end of 2023. Since...
  5. zoo123

    How to correct pin joint to fixed joint Concrete PEDESTAL TO BASEPLATE

    Dear Klitor, Thanks. By redrilling i am sure the orientation of the Flanges will be changed to take moment and the bolts will be outside the flanges. Would there be any other option pl.
  6. zoo123

    How to correct pin joint to fixed joint Concrete PEDESTAL TO BASEPLATE

    Dear jayrod, Thanks for the reply. It is my project turnkey. As i said an error now manifested. What you believe could be the failure modes when i redrill on the other side.
  7. zoo123

    How to correct pin joint to fixed joint Concrete PEDESTAL TO BASEPLATE

    Dear Jayrod12, Thanks for the reply. My question, was by rotating the location of the anchor bolts by 90 deg. the constraints would take moment loads. Just by regrouting. Would it yield the desired need of taking care of the moment load. Yes, the bolts dia are 20mm for now. the pedestal size...
  8. zoo123

    How to correct pin joint to fixed joint Concrete PEDESTAL TO BASEPLATE

    Greetings to all. I seek your inputs for correcting a Civil error pl. in our site for Constructing A 500SQFT NEW sTEEL SHED By mistake the anchor bolts have taken up an orientation, that will convert the structural rigidity to the Pivoted type that was planned initially for a fixed type. Now...
  9. zoo123

    Frequency fluctuation in a transformer secondary

    Hello IRSTUFF and Waross my sincere thanks to both of you for the inputs i receive from you. We planned the following interim corrective actions for now temporarily 1. customer not interested to pot but help us out by pouring a wax on the box to avoid jumps and harmonics due to air gap. etc. 2...
  10. zoo123

    Frequency fluctuation in a transformer secondary

    Hello WAROSS, COMPOSITEPRO AND IRStuff your inputs had been valuable to understand what has gone wrong. While had not validated the root cause, it is simple that the we have 12w and 22watt transormer. the 22 watt transformer apologies i did not say about it. is not functioning because , the...
  11. zoo123

    Frequency fluctuation in a transformer secondary

    hello seek your help. We have wounded a transformer with 230V 50 HZ PRIMARY And 2200 V Secondary and 5milli amperes at Secondary. This transformer is used for ac ioniser application. The input circuit has a fuse and power LED connected in series and to primary windings. The earth is connected...
  12. zoo123

    TRANSFORMER POWER SUPPLY OUTPUT FREQUENCY HIGH AND ERRATIC

    we do not have a schematic yet. but the transformer gets its primary through an LED INDICATOR AND PRIOR TO WHICH THE FUSE IS KEPT. We have a filter for removing the noise first.
  13. zoo123

    TRANSFORMER POWER SUPPLY OUTPUT FREQUENCY HIGH AND ERRATIC

    AS OF NOW, HE IS CLUELESS. HENCE our request to experts like all of you. Thanks.
  14. zoo123

    TRANSFORMER POWER SUPPLY OUTPUT FREQUENCY HIGH AND ERRATIC

    FOR A sTATIC IONISERR WITH ac ionisation, the TRANSFORMER WITH HIGH VOLTAGE LOW AMP. WAS MADE. bUT THE Supplier transformer fluctuates and shows up frequencies of 00 to 400 hz. Not sure what might be the issue. The voltages and ampere levels are decent. But, the sinusoidal freuency is not good...
  15. zoo123

    AREA MOMENT OF INERTIA OF WELDED bEAM

    i am working on a cost effective ramp to carry a load of 100kgs on very light weighted structure. I hit a road block now, on a frame horisontal and 415mm wide X 650mmm long. with a thickness of 20mm. This frame should be below a kg weight but carry a static load capacity of 80 to 100kgs. With an...
  16. zoo123

    RC Transmitter - Variable type possible???

    Dear friends, I wish to share some good news that i was able to iteratively vary the frequencies in the 4 RC Cars by varying the variable frequency transformer. And I succeeded decently. They are not interfering now. But, when they are very near there is a few cars interfere. But, i am happy to...
  17. zoo123

    RC Transmitter - Variable type possible???

    Greetings, I was reviewing with a chinese toy manufacturer today and she said, 2.4GHZ rc TOY Cars do not have interference and i can buy them as much as i want rather than going for a diff. frequencies. Not sure , how it is possible. Google search also indicates the same. Want to share and...
  18. zoo123

    RC Transmitter - Variable type possible???

    My sincere thanks for your inputs and link to read the book. I AM Still trying and will get some answer tomorrow.
  19. zoo123

    RC Transmitter - Variable type possible???

    All, My sincere thanks for your views. Still trying. There is a 2.5 turn variable inductor prior to the antenna in this RC TOY CAR Transmitter. I used a flat screw driver( a tiny one) and tuned it a bit crudely. I then checked if the car is responding to the forward , reverse, left and right...
  20. zoo123

    RC Transmitter - Variable type possible???

    Thanks. I am planning to vary the frequencies. Did a search of the chinese manufacturers of rotary variable inductor coils and asked them the sensitivity in terms of Frequency per turn. Will they respond me ???? [ponder] Meanwhile, the inductor is so small, i have to be careful to turn it...