This is a very difficult task that you are presenting. Professional associations in Canada typically ananlyze professional engineering salaries with the full range of spectrums from the most senior personnel to the junior woodchuck.
Costs for geotechnical investigations are suspect and I doubt...
You have a very interesting situation. Most Businesses are valued on their EBITDA which is annual Earnings Before Interest Taxes Depreciation and Amortization. This number comes right off the companies tax returns and then a multiplier is used. In times of good economics (which was in 2006)...
dgillette,
I completely agree with you regarding tackling projects that are not in your area of expertise. I also agree that on larger projects, a team of technical specialists is required and yes the project this young person has described appears to be a large project.
I do feel that the...
geotechniqa,
I can appreciate your situation. As I was a young engineer once, I understand, as an employer, I want to see what you got to offer. Why are you getting that salary and bonuses and how can you contribute to the firm?
You may want to really think about turning tail on this one and...
hokie66,
Thanks for your comments. You are correct, that they are expanded base piles, but not to be confused with belled piles. These are cased and the pile consists of a gravel and portland cement mixture.
There has got to be some design data out there for this..........I have seen AMEC...
Well before we throw the baby out with the bath water......check the compressive strength of the cores to confirm. If bad, then we have a problem......were they all bad....or just a few......so do we core them all or is it just a select few........if it is just a few, possibly installing a...
Ok, I've done several searches on this site over the last four years for Franki pile design and have always returned empty handed.
Every once in a while, in my travels, I come across a site that would be ideal for Franki piles.........a very competant bearing strata located approximately 35 to...
I would say no..........by removing the gravel from the sample, you are changing the soil. The gravel portion is part of the soil matrix.........unless they will be screening the soil through the 4.75 mm sieve prior to placement or it's intended use.
For example you have 10% gravel, 45% sand...
Again I am amazed with everyones posts here. I think they are all great.....keep them coming. I think the variety is really cool as well.....some are religious based and some are more rules of thumb and others are just hey this seems to be working for me....try it out. I really think this...
Wow.....unbelievable....most of the technical posts I write take several days for people to reply and usually they don't have too much to say and usually it is just a couple responses. I was just courious to see what kind of response I would get to this type of post and it is obvious that...
We've all heard the joke engineers have a spouse and something on the side...so while they are occupied with eachother the engineer ducks back to the office to get some work done. How many of you engineers out there are going through some "significant other" problems? How many of you....know...
I am in Canada and use a CSA method for testing water soluble sulphates. I would be interested in taking a look at the BS1377 method that you are using to see how it compares. Is there any way you can send me the BS1377 testing procedures?
I really feel for new home owners with foundation problems like these. It really is frustrating as hell, insurance companies seem to be there to protect the contractor instead of the providing the insurance that the new home owner needs.
I see that AWHarris (original thread) is attending...
Why don't you install several large air fans/vents, at either end of the building. The installation of these systems are pretty inexpensive and the more the better. Keep in mind you will not only have to supply enough oxygen to remediate your soil, but there could be some pretty serious...
Is this a heated garage or unheated? Is this settlement or maybe this is a heave issue? Does it appear to be settling close the the attached house or at the end of the garage away from the house? What is the drainage like around the garage (good positive drainage away from all buildings)? Is...