Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. coachk

    Chemcial Costs

    Anyone know where I might be able to find current prices for various chemcials used in BWRO potable water and sanitary wastewater reuse (for irrigation) treatment plants. Assuming size of facilities are 0.5 - 1.0 MGD. Chemicals required and approx rates could be: Ferric Chloride Sulphuric...
  2. coachk

    Potable Water Chlorination

    All: Thanks for the help! sbush: what would typical cost of calc hypo tablets on a $/lb basis, assuming usage is say 10 lb/day?
  3. coachk

    Potable Water Chlorination

    I am looking at possible disinfection systems for a 1 MGD potable water treatment facility for a resort. Would a hypochlorite dosing system be considered `typical' for this type/size facility?
  4. coachk

    Puerto Rico Soil Resistivity

    Anyone know of typical values of soil resistivity for the southern coast of Puerto Rico? Thanks!
  5. coachk

    API 5L Grade X42 Pipe Bending

    DrillerNic, Thanks for answering. Would the 50 x pipe diameter bend radii change for different grades of pipe? Or would this be considered a safe value that can be accomplished in the field?
  6. coachk

    API 5L Grade X42 Pipe Bending

    Hi! For installation of a 24-inch SCH 40 API 5L Grade X42 fuel oil pipeline, anyone know what the maximum degree of bending that can be field accomplished without damaging the piping? Thanks for your help!
  7. coachk

    API 13 Fuel Oil Viscosity vs Temperature

    I very much appreciate the responses, as this is a new area for me, and I am learning a lot about the subject. From what I have been reading through this thread and other areas on the net, it is apparent that the low temperature should be modified from the 90 deg F. It appears that 100 F...
  8. coachk

    API 13 Fuel Oil Viscosity vs Temperature

    Thanks for the quick responses. It is no. 6 fuel oil for a power plant. The closest that I was able to find is that API 14.5 has a min & max viscosity of 150 - 480 cST @ 50C (122F). The API 13 fuel oil is typically delivered at a temperature of 140F, but can cool to close to 90F. I would...
  9. coachk

    API 13 Fuel Oil Viscosity vs Temperature

    Help!! I have spent a lot of time searching for information regarding the viscosity of API 13 fuel oil at various temperatures. I have searched through various links given in answers to numerous threads, but keep coming up empty-handed. Thanks for your help!
  10. coachk

    Protective coating for RO skid frame

    Hi! I have been told that epoxy powder coating is a good protective coating for a seawater reverse osmosis skid frame made of either aluminum or welded carbon steel? If that is correct, how is it applied (electrostatic, baked, etc.); or is there another coating which will provide better...
  11. coachk

    Oil pipeline

    I have been asked to perform an independent (out of discipline) review of the design of pipeline(s) used for the onshore transport of #6 and #2 oil. Although there will be experienced engineers responsible for the detailed review, and my review is intended to be more of an engineering...
  12. coachk

    Rubber lining multi-media pressure filters

    cub3bead, Thanks for the response. I have the same concerns regarding abrasion of the epoxy lining, and have seen what were reported to be epoxy coated valve disks that failed miserably in seawater service....could have been a bad coating job, but I'd rather that not happen with these filters...
  13. coachk

    Rubber lining multi-media pressure filters

    Anyone have experience with rubber lining multi-media pressure filters? In particular, thickness of the lining. The filters are to be used as pretreatment for an RO plant, and can receive water from 2 different sources: potable water with high SDIs, and seawater from wells.
  14. coachk

    Multi media filters

    Anyone have experience with rubber lining of multi-media pressure filters? Filters are to be used for RO pretreatment, with 2 different feed sources: potable water with high SDI and seawater from wells. I am concerned about the thickness of the lining necessary.
  15. coachk

    caisson cost

    Anyone know of typical construction cost ($/ft) for 24" dia caisson x 60' long with 8-#8 bars and #4 ties @4" O.C.?
  16. coachk

    `Rule of Thumb' Pipe Velocities

    1969grad & mjcronin, I tried the Advanced Search prior to posting the question, and thought that I was using the most extensive search by clicking on the `All' or `Any' word search...but kept getting the `Sorry' message. After 1969grad's response I tried searching again using every combination...
  17. coachk

    `Rule of Thumb' Pipe Velocities

    Howdy All, For water flow in pipe, anyone know of a source for `rule of thumb' (typical) maximum acceptable velocities in different kinds of pipe? Thanks!
  18. coachk

    `Air Operated Diaphragm Pumps

    Hi all, I am pumping a mixture of oil and water, and sometimes dirt out of a sump and into a tank (from the tank it will be gravity fed through an oil/water separation process. I have been told that the best pump would be an air operated diaphragm pump, as it will not emulsify the oil. I need...
  19. coachk

    Pipe Support Span

    Thanks for the quick response....particularly to MJCronin - the table was just what I needed.
  20. coachk

    Pipe Support Span

    Anyone know of a good source for maximum spans between supports for various schedules of stainless alloy piping?

Part and Inventory Search