Thank you for good reply for me!!
VP, pumping temp, suction and discharge pressure are as following :
-----------------------------------
Temp(mini/max) = 5 / 98
SG = 0.987/1.158 @ 5 C
VP(kPaa) = 94 / 94
Vis (cP) = 0.3 / 2.0
Capacity (m3/h) = 26.9
Discharge press...
Anybody please correct my seal selection for following :
Service : Centrifugal Feed Pump
Liquid : Hot lime softener sludge slurry
Seal & Plan : Single mechanical seal + Seal plan 23 ()
Liquid properties ----------------------------------------
TDS = 933 mg/l Total Hardness(as CaCO3) =...