  1. coatsandrew

    Water pressure at end of a outfall?

    I'm trying to determine the water pressure at the exiting end of a 66" storm water pipe. Max flow is 10 ft/s. Suggestions? Thanks
  2. coatsandrew

    Type of Cement to use in brackish water?

    I have a project where we are placing a concrete slab (10'x3'x2') within brackish water (Chesapeake Bay area) to act as an anchor point for a Water Treatment Plant's outlet piping diffusers. Originally, it was specified to use Type V cement in the concrete mix. The contractor states that they...
  3. coatsandrew

    ATFP for Pre-Engineered Buildings - UFC 4-010-01

    Has anyone had success with requiring the Pre-Engineered Building Manufacturer to design their building for the Blast Requirements of UFC 4-010-01? The building's current conceptual design does not allow for all building components to fall within the Assumed Parameters of Table 2-3 (i.e. main...
  4. coatsandrew

    Costworks - professional design line item

    Does anyone know if RSMeans CostWorks has line items for professional design services? I would assume that it'd be a line item based on type and square footage of building, or a percentage of the estimated construction cost. Thanks.
  5. coatsandrew

    Black Hawk Wash Rack - wash water

    Does anyone know where we can find design information for what is contained is wash water from washing Black Hawk helicopters. We are installing a new wash rack for the Army National Guard and need to know what the treatment equipment needs to be designed for before outletting to SAN line.
  6. coatsandrew

    Estimating DGA

    I was asked by a contractor how much area would a ton of DGA cover at a 4" depth? I don't have any experience with DGA, but to me it's more of a mathematical question regarding densities and volumes. It is that simple, or are there formulas for these characteristics associated with DGA?
  7. coatsandrew

    Lintels in ICF Walls

    I'm designing a 2-story structure with exterior ICF bearing walls. The ICF manufacturer (with Contractor ties) is requesting we keep all lintels within coursing of their 16 7/8" high ICF wall blocks. I have a few spans over 1st floor windows that have floor beams from the 2nd floor bearing...
  8. coatsandrew

    Correct Galv Deck to Heavy Timber Truss Fasteners???

    Does anyone have experience with connecting 20 gauge galvanized roof deck to heavy timber trusses? The major concern is excessive corrosion from the galvanizing/pressure treatment interaction. I've been told to spec a screw with a stalguard coating, but Elco does not have shear or pullout...
  9. coatsandrew

    Therapy Swings - Design Load?

    Does anyone know of any IBC 2006 design load requirements for special indoor equipment that will be hung from the roof structure of a classroom? I need to design for therapy swings in a special needs classroom, but I can't find much information on the design requirements. I was thinking of...
  10. coatsandrew

    LEED and Concrete Mixes

    We're starting to design a new school that will obtain a LEED Silver (or higher) rating. My question is what proportions/requirements for slag, fly ash, etc. are typically specified for concrete mixes in the 3,000 to 5,000 psi range? I would like to contribute to the LEED credit as much as...
  11. coatsandrew

    Fiber-reinforced concrete, help with research.

    My department is trying to verify that we are using industry standards in our fiber-reinforced concrete slabs on grade, stairs and sidewalk typical details/specs. Can anyone point me in the right direction for latest standards and practices? Thank you