  1. maneesha0702

    API 650- Annex I- Sec I5.5

    As per this section "If drain pipes are used around the tank perimeter, they shall be at least NPS 1 in diameter and have a minimum wall thickness of Schedule 40. The pipes may be perforated in the undertank area to improve their leak detection function. The inner ends and perforations of the...
  2. maneesha0702

    Seismic design for Zone 1, Elastomeric bearings, AASHTO Sec 3.10.9.2

    I am designing a bridge which is of 4 spans and the seismic zone is 1. The total weight of superstructure is around 2000 kips( 200' length , 4 spans)and all the beams are on elastomeric bearings. When I am checking for a pier what is the lateral load I should use. As per sec 3.10.9.2 my As...
  3. maneesha0702

    Steel Joist failing shear remedy

    I am checking a 28k10 joist for additional loads. However the joist is failing in shear. What is the best remedial measures that should be adopted? I am enclosing the joist calculations for reference. Any help is appreciated.
  4. maneesha0702

    Conical Roof Calculations

    I had modeled a conical roof and I checked the stresses with API 620. The results are way off. Can somebody highlight where I had gone wrong? I had attached RISA model with Hand calculation. The bottom dia is 12 ft and the top dia is 1 ft and the height is 1 ft. The Live load is 25 psf. The...
  5. maneesha0702

    Conical roof Deflection and stress formula

    Where can I find the formulas or design particulars for the same. Any help will be greatly appreciated
  6. maneesha0702

    How to model Monorail in RISA

    I am modeling a monorail in RISA. The monorail is S12 X 35 with C10 X 15.3 cap welded on top. The way I modeled is I created a new section and input the salient properties i.e I,Z,A,d. These values were calculated on basic principles. The other properties I used some approximate values. The...
  7. maneesha0702

    Impact Load Analysis

    We were checking for a large lift where the load is heavier than 100 kips. The velocity with which this load is placed on the support is 20ft/min. How do we calculate the impact load. I tried to equate the kinetic energy to strain energy. However this produces an impact factor of greater...
  8. maneesha0702

    API Foundation for Machinery

    In API code for designing foundations for machinery(Pumps) there is a code requirement that the width of foundation should be atleast 1.5 times the dist from base to Centerline of Machinery. Is the base the bottom of concrete or the base plate of the machinery
  9. maneesha0702

    Foundation for Machinery

    There is an empirical rule that the weight(mass) of the foundation needs to be 3 times the machinery (API). How should the weight be calculated? Is it below grade only? If so is there any clarification any write up or commentary any where.
  10. maneesha0702

    Asphalt Tank resting on Concrete Thermal stress Calculation

    I am checking a Asphalt Tank with Temperature at 280F resting directly on 6" slab with reinforcement at top with a cover of 2". How can I calculate thermal stresses or crack widths? ACI code drew a balnk.
  11. maneesha0702

    ACI Appendix D- Bolt Tension Calculation

    I have two questions regarding Anchor rod. The first question is if I use a sleeve will the effective length decrease by the sleeve length. The second question is a)if you use 4 bolts ( bolts are equidistant in both directions)and if the wind is acting perpendicular to two adjacent bolts...
  12. maneesha0702

    Box culvert

    I am checking a boxculvert. It is a twin cell with 27" sidewalls and 18" midwall. The ht is 15' and span is 20' for each cell.The boxculvert supports 19.5 ft soil on top. The top slab is 42" and has #11@6" for _ve reinforcement and #9@6" for +ve reinforcement. The bottom slab is only 33"...
  13. maneesha0702

    Question regarding Box culvert formula in AREMA

    I am checking a existing twin cell box culvert for new loads. In AREMA there are formulae given for moment calculations. Moment of inertia of box culvert top slab gross section is equated to Isubscript S. Moment of inertia of box culvert wall gross section is equated to Isubscript W. I am...
  14. maneesha0702

    pipe passing through proposed concrete wall

    I am designing a wall around existing pipe through which liquid passes at 200degrees fahrenheit. What precautions should I take for laying concrete. Should I install any sleeves?
  15. maneesha0702

    Design of hangers for oil tanks

    I am designing fire prevention system for oil tank. The fire prevention system has 10" & 6" lines at 3rd level i.e. 24ft above grade and 24" from top. (Ht of tank is 48' and dia is 220'). The hangers need to be attached to the shell. The shell is designed for hoop tension and the...
  16. maneesha0702

    Formula for Tangential force for Hangers Omar Blodgett

    In section 6.6 of the design of welded structures there is a formula for Calculating Tangential Tensile Force T=K1*f1 K1 is dependent on the no of hangers and Table I gives the values for no of hangers upto 8. Does anyone what are the values beyond 8.
  17. maneesha0702

    cantilever retaining wall

    Do a cantilever retaining wall need to be below the frost depth at the toe?
  18. maneesha0702

    Modeling WT in Risa.

    I am modeling a Truss in RISA. I am using WT members as Braces. These braces are modeled with Flanges horizontal for horizontal braces. As they are connected to Gusset plates there may be bending due to eccentricity. Can this be taken into account by the model. If not what should be remedial...
  19. maneesha0702

    Mdeling 3/4" rods with turnbuckles

    How do I model the above in Risa. I modeled them as eyebars and they are not failing or bearing any load. However they are showing huge deflections of the order of 80 inches for a length of 25 ft.
  20. maneesha0702

    Extra strong reinforced concrete pipe(1946)

    I have some drawings which show a 96" concrete pipe erected in 1946. Now the client wants to add a 24" pipe to the 96", by making a opening. Where can I get details of this pipe? Drawings just show Extra strong reinforced concrete pipe.