  1. CROWN06

    Base Plate design AISC 13th edition

    Any body has any freeware or spread sheet for design of base plate as per AISC 13th edition, ASD or LRFD.
  2. CROWN06

    Just a thought

    The shallow the truss, less longer the members and hence more axial capacity. So apparently no need to strengthen members if we shallow an existing deep truss or O.W.S.J. Probably it is needed when we check it for axial forces from moment, i.e we find out moment at mid span and depending on...
  3. CROWN06

    Mat footing

    I need to design a square mat footing. It has four concrete pedestals symmitrical arrangement. Any idea how to find maximum moment and shear + other tips on what is needed to be done.
  4. CROWN06

    Maximum number of Bars in Beam

    Does anyone have something handy to find out what will be the maximum number of bars in beam as per ACI 318-05. In case. they do not fit in one layer than what are the if and buts for second or higher layer, stirrups requirements and detailing. Thanks.
  5. CROWN06

    Double angle gross area.

    I am trying to model a truss using SAP2000. I am unable to understand that in output Why Sap can reduce the cross sectional area of double angles. To me the area should be constant But as I enter different spacing for back to back legs, x-area changes.
  6. CROWN06

    Retaining wall footing

    rho minimum = 0.0018 x hf / ( 2 x d), where hf = height of footing and d is hf-cover. Is this formula ok as per ACI 318-05 for minimum steel to be used in concrete retaining wall footing.
  7. CROWN06

    Concrete Retaining wall- FOS

    Which code explains the limit for minimum FOS for overturning and sliding of reinforced concrete wall (and under which clause)
  8. CROWN06

    ASCE 7 -05, Clause 2.4.1

    If you read at the end of allowable stress combinations, they do not allow for increase in allowable stress. Does this mean we cannot increase soil bearing capacity 33% due to wind or seismic load.
  9. CROWN06

    Pile cap reinforcement above pile

    Is it as per ACI detailing standard that the pile cap bottom mesh should be 12 inch high and pile steel should enter into pile cap run vertically 12 inch and than bend over pile cap bottom steel.
  10. CROWN06

    Minimum (As) reinforcing steel in footing

    In footings many engineers tend to ignore this minimum steel ratio bw x d x 200/fy . Does ACI or any thing relevant confirms this anywhere. Thanks in advance.
  11. CROWN06

    circular footing design

    Any guideline on design of circular spread footing
  12. CROWN06

    circular pile cap deisgn

    Anybody has any freeware or spread sheet for deisgn od circular pile cap for Tanks.
  13. CROWN06

    Open Web Steel Joist - Depth reduction

    I have existing 24 inch deep steel joist spanning 40 feet. At one end, for about twelve feet I need to reduce the depth to 12 inches. Any ideas.
  14. CROWN06

    Can we cut a Post tensioned deck

    We have a post tensioned deck bridge. The tendons are in both directions (like two way slab). Can we cut bridge in half for stage construction?
  15. CROWN06

    BRIDGE DESIGN & ANALYSIS SOFTWARE

    I am looking for some feedback as to which software is good for bridge analysis and design while working in CANADA
  16. CROWN06

    #9 bar broke while bending

    I had a #9 bar bend at 90 degree. There were total 56. 4 of them were broken while a Labour tried to move them for adjustment.Any thoughts on that, how concerned u r with the quality of steel or wrokmanship.
  17. CROWN06

    Relaxation of bolt

    When bolt is tensioned, what will be relaxation losses over period of time?
  18. CROWN06

    wind load on wall

    For a common building, windward wall say has 15 psf positive wind pressure and leeward wall has 11 psf negative pressure. In same vicinity if we have just one simple cantilever wall, it will be deisgned for 15+11 = 26 psf wind load?