Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations MintJulep on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Thuba
  • Content: Threads
  • Order by date
  1. T

    Flow inconsistence

    l have a pump rated at 4m3/h and 35m head. lt pumps edible oil through an economizer and the to dearator with some nozzles. From the dearator there is another pump feeding a vessel (rated 9m3/h and 40m head) and there is a flowmeter reading 1800L/h (1.8m3/h). Some how the dearator gets empty or...
  2. T

    pumps

    l have a pump rated at 4m3/h and 35m head. lt pumps edible oil through an economizer and the to dearator with some nozzles. From the dearator there is another pump feeding a vessel (rated 9m3/h and 40m head) and there is a flowmeter reading 1800L/h (1.8m3/h). Some how the dearator gets empty or...
  3. T

    pumps with different kw rating

    l have 2 pumps one is 2.2 kw and another 5.5 kw. l have 2 questions regarding these. 1. The higher the kw rating doesnt imply higher flowrate, as one with 2.2kw has a higher capacity than the one with 5.5kw? 2. Can l replace the motors with one with the same kw rating but differene rpm? lnstead...
  4. T

    clogged suction or discharge pump linr

    Say l have a clogged discharge line, the pump current drawn by a pump should not drop; just as starting a pump with discharge valve closed (0 flow). Also a clogged suction line shouldnt result in less current drawn since flow is low. l am confused as to how both cause increased current drawn?
  5. T

    Screw pump

    Attached is a screw pump with a motor coupled on the side. The pump shows the direction it should run,but that will require motor to run anticlockwise and does not pump. lt only pumps when the motor runs clockwise and the pump running wrong direction.
  6. T

    photovoltaic dust accumulation

    Goodday, How can l use AI to measure dust accumulation on solar panels and automatically clean them?
  7. T

    Siphon

    l have a tank 2m ×2m×2m. So my volume is 8m3. l want to be able to to siphon the liquid at 16m3/h, using it as a purge line for my hotwell. l could have installed a pipe and a valve at a bottom of the tank, but the problem this will need a shutdown. My question is there any equation to calculate...
  8. T

    Estimating steam consumption on a steam distillation column/ deodorizer

    We use sparging steam fo agitation and stripping in a deodorizer column. Is there a way l can calculate steam consumption of the continuous deodorization column. We use superheated steam, we superheat saturated steam from boiler house using thermic fluid in a superheater. Attached is a schematic...
  9. T

    Pressure drop vs volumetric flowrate

    l saw this article on LinkedIn, and applying this theory to practical, didn't add up. The way we reduce flowrate to a vessel, either for a liquid or steam is by restricting flow, increasing pressure drop and resulting in a lower flowrate downstream of the valve. ln this case it seems, for liquid...
  10. T

    Pipe inlet design

    Goodday. l have a vessel heating edible oil using thermic fluid through a heating coil. The inlet of the thermal fluid the pipeline is looped, l was wondering whats the purpose of looping. See attachment!
  11. T

    mixing ratios in a batch process

    Goodday. What is the minimum mixing ratio in a batch process? Say l have a 10 000L of crude oil and l want to add 0.1% phosphoric to the oil. To what volume should l dilute my acid to get effective mixing in a batch mixer? l figured if l mix 10L of acid to 10 000L of oil is too much of a volume...
  12. T

    pump and motor

    Goodday, l have a pump rated 5 5KW/2900rpm and l plugged 3.7kw/ 2875rpm motor. Will this damage the motor or pump?
  13. T

    Flowrate in a valve

    Goodday. Does a valve reduce volumetric flowrate. l ask because we use valves to reduce flowrate, but according to valve software, only pressure drop will be realized, but flowrate will not be affected. See attachment. Thanks
  14. T

    Steam consumption

    Goodday, l want to measure steam consumption(stripping steam) of a deodorizer. l dont have a flowmeter or a nozzle, just a pressure gauge. Please find attached the schematic of my problem.
  15. T

    Non return valve

    Goodday, Does a non return valve have a valve flow coefficient? l want to calculate mass flowrate of steam through a non-return valve. Your assistance will be much appreciated.
  16. T

    motor

    goodday, my plant flow diagram state l require 10HP compressor. Does it mean any 10HP compressor will work or l need further information?
  17. T

    Pump selection

    Goodday, l have the following PFD and it says l want 5hp pump, does this refer to the pump itself or motor? lts P601-A