Thank you both very much for your response. One last question. Would the availability of increasing the water flow of the hotter (89F) cooling tower water above the existing 45F water flow to the mixer (9 GPM) alter these conclusions to any significant amount?
Thank you very much for the responses.
Please see attached drawing, which describes the process. The process is continuous for about 2 hours, then a new container of dry powders is placed on top of the mixing machine, which takes 20 minutes to complete. A new 2 hour mixing process then...
I would appreciate any feedback regarding the negative effect of increased inlet water temperature into a cooling jacket surrounding a mixing machine.
My company uses a mixing machine that mixes together various dry powers in the manufacturing of brake shoe friction material. The mixing...