Without seeing your Template is difficult to check. But let me guess. You can have different End Conditions for the Left and Right of the Levee. Let's say the left side end condition to the bottom of the pond is a contstant -50.0%. Make sure the end condition for that side has "End Condition is...
Are you using a decision table or are you letting the template solve your toe of slope? (With cut and fill backbones)
I would try running the model as "backbone only". This may narrow the problem.
Lot's of things to check.
Do you drop templates at all of the event stations? I usually turn them all off.
Where did your original ground DTM come from? How was the DTM developed? Ground Survey or Aerial Photogrammetry?
How was your horizontal and vertical generated? Was the horizontal...
About the only data that can be switched to InRoads is the TIN file. You would have to use LandXML to perform this task. Export out then import in to a InRoads DTM. There are more variables with InRoads DTM's such as features. Features are the 3d lines that comprise your DTM, only features are...
You need to make the styles that you do not want in the DTM as DNC. Do not contour. This can be accomplished in the Survey Feature Table file on in the DTM, you can toggle on in the features under surface>feature properties and click on "exclude from triangulation"
Yes you can.
1.) Make cells out your rectangle shapes in Microstation drawing them to actual size.
2.) Create styles and symbologies for the rectangles using default or plan point. Edit the plan point area for the symbology and change the option to cell. Browze for the specific cell that you...
I have a custom linestyle resource file that was created with metric units. We have a job that requires the use of imperial units. The resource file was created utilizing a 1:100 scale factor in metric. With the proper conversion we are able to set the linestyle scale to 7.874 for a 1”=20 scale...
You have to use a color other than 0. Try number 16 on the standard color table. White (0) has values of 255,255,255. Number 16 has 240,240,240 which is a little grey. I suggest that you edit a number to use 250,250,250 or a variable of those numbers.
Hope this helps
Champ
under Microstion help, consult linking and embedding objects in Microstation. Axiom is no longer needed.
Linking and Embedding Objects in MicroStation
A linked object is a document that can be viewed from its container application, but it actually exists in its source application. An embedded...
I gave up as well. I found it is easier to just to use selection sets and change symbology. It's the longer way but the safe way. If you use InRoads for planametric mapping, you can try to change your DTM to a feature based model then display it as mapping.
if reference files are involved, you can change the sequence and have the reference files "layer" so that the filled elements are on the bottom of the list and the other elements go on top. File>Reference>Settings>Update sequence. If that does not work and reference files are not envolvled and...
Reference Files
Separate the files of single line, ladder diagram and wiring diagram. Use reference files for each file and your changes will automatically update in a contract type plot file sheet.
YOU CAN TRY TO MAKE A SELECTION SET OUT OF THE ELEMENTS IN QUESTION. THEN GO TO ANALYZE ELEMENT. CHANGE THE PROPERTIES TO SNAPPABLE. THEN HIT NEXT AND IT WILL GO THE NEXT ELEMENT IN THE SELECTION SET AND CHANGE IT AS WELL. CONTINUE TIL THE END OF THE SELECTION SET.
GOOD LUCK