Please read through ASTM A 262.The function of IGC testing, B,C,D,E are to detect the level of sensitization and loss of intergranular corrosion resistance. A262 Practice A is done as a quick screening test for 300 series steels, as explained previously. It's Oxalic Acid Etch Test for...