Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by munich

  1. munich

    Treatment of waste water of a conference center in Jamaica

    A conference center for about 10,000 visitors will be built near the city of Kingston, Jamaica (Old Harbour). Are there any collegues, which might be able to come up with design hints, tips, comments etc. I would be grateful to share opinions and to listen to advices. My background: I am a...
  2. munich

    Residual COD problems in treated fast food wastewater

    COD/TSS problems at effluent from fastfood WW treatment in Jamaica W.I. We have the following problem with one treatment plant: The customer is a fastfood restaurant, we treat about 5 m3/d of the combined kitchen and sewage WW after extensive grease/scum and primary treatment/removal in an...
  3. munich

    Can increase of Oxygen supply break down more COD in an AST plant?

    bimr, why do you think its a lagoon system? Its a small TP behind a restaurant. Cheers munich
  4. munich

    Mixing distance in a pipe

    You guys have bauxite industry nearby? They will love to sell you caustic since it's their by-product, but don't use lime, please... 30" pipe? that's a large TP. Cheers munich
  5. munich

    Can increase of Oxygen supply break down more COD in an AST plant?

    bimr, thanks again. Detention time is at the lower end, it's about 10 d, however we have very limited space, cost pressure etc. (site is in Savanna la Mar, Jamaica, near Negril). Well, with respect to your MLSS figure of 1,500 mg/L: this converts to an Imhoff volume of about 190 ml/L at an SVI...
  6. munich

    Waste Oil Recycling

    bimr, thanks for your post. I will not try myself but I needed to know if we can trust one these firms here in Jamaica. Cheers munich
  7. munich

    Waste oil recycling

    adrianviorel, thanks for your post, these are bad new, I hoped that bacteria etc. require water for their metabolism (osmotic pressure on membranes etc.). Since these oils contain lots of unsaturated fatty acids they require hydrogenation before being suitable for a blend with reg. diesel as...
  8. munich

    Waste Oil Recycling

    Does anybody know if bacteria, viruses etc. survive in waste oil? The promlem is the following: We need reduce levels of oil, fat and grease to enter the grease trap of a fast food restaurant. By using a separating device such as a dipper we will be able to separate a good deal of these...
  9. munich

    Can increased oxygenation break down more COD in a WWTP?

    rbcoulter: thanks for your post, I will go there, MLSS increase makes sense a lot. Cheers munich
  10. munich

    Can increase of Oxygen supply break down more COD in an AST plant?

    rbcoulter of the water treatment forum suggests increased MLSS. I like this. Thanks again for all replies. I am glad I found this site. Cheers munich
  11. munich

    Can increased oxygenation break down more COD in a WWTP?

    We treat effluent of a fast food restaurant in an activated sludge treatment plant. Our effluent is quite turbid, TSS levels around 50 mg/L and COD levels of the effluent are around 300 - 500 mg/L. COD inflow is around 1,500 mg/L. BOD5 levels are very low, around 1-3 mg/L. MLSS is about 200...
  12. munich

    Waste oil recycling

    Does anybody know if bacteria, viruses etc. survive in waste oil? The promlem is the following: We need reduce levels of oil, fat and grease to enter the grease trap of a fast food restaurant. By using a separating device such as a dipper we will be able to separate a good deal of these...
  13. munich

    CO2 - Can it be useful in a Wastewater treatment plant

    JasonMoore Check the solubility of CO2 in water. If I remember right it's low. TerraSouth is perfectly right with his hint towards de-nitrification, however CO2 and its solubility may be the limiting factor. Cheers munich
  14. munich

    Can increase of Oxygen supply break down more COD in an AST plant?

    TerraSouth, thanks for your message. I agree with what you say. The problem of the aeration tank is that it's too small thus detention time insuffucient. We have/had massive space problem with the location. Also cost matters played a role. Since the stand-by aerator is there already, we...
  15. munich

    Can increase of Oxygen supply break down more COD in an AST plant?

    We treat effluent of a fast food restaurant in an activated sludge treatment plant. Our effluent is quite turbid, TSS levels around 50 mg/L and COD levels of the effluent are around 300 - 500 mg/L. COD inflow is around 1,500 mg/L. BOD5 levels are very low, around 1-3 mg/L. MLSS is about 200...