Thanks @FluidPowerUser ! Would the following scheme work?
I would switch off the solenoid the instant the valve movement stops so the A/B lines don't bleed down through the orifice on the LS signal on the tractor.
However if I then want to start movement again I would turn on the solenoid to...
I am thinking that my scheme will cause the pump to not see a difference in P and LS pressure. Therefore when I turn on the LS solenoid it will immediately ramp up to maximum pressure. Is that right?
If so would I be better off connecting the solenoid and check valve to A/B? If so, how would I...
Hi,
I am working on connecting a pair of closed-center proportional control valves in parallel to my tractor. The valves have P, T, A and B connections. The tractor has a closed center pressure-flow compensated system that has a load sense port. The pump has a max output of 25 GPM at 2,500 PSI...