Hi
excuse me
from the instruction manual of the pumpwe have
The set point for the maximum deviation is of 0.03mm per meter length of the shaft.
And I have 0.08mm for one meter and half the length of shaftpump.
after disassembling the pump ,we noted that also bushings are out off tolerance and...