Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. gregg098

    Dry Scrubber Ca/S Ratio

    I am trying to calculate the Ca/S ratio for a dry scrubber and need some clarification. For sulfur, I know the the percentage sulfur in the coal through analysis. Tons coal x % sulfur x 907184.74 g/ton / 32.0655 g/mol = Moles sulfur For calcium, I know the amount of CaO in the lime. Would I...
  2. gregg098

    Volume of Nitrogen needed for boiler hydro

    Thanks for the feedback. Out of curiosity, how is steam in the boiler when online less dangerous than Nitrogen while offline? The compressibility factor is about 10% more, but steam is still a pretty big energy source at 1000 F and 2500 psig.
  3. gregg098

    Volume of Nitrogen needed for boiler hydro

    Since this is most likely A LOT of N2, we could press up to about 130 psi with compressed air first.
  4. gregg098

    Volume of Nitrogen needed for boiler hydro

    My plant would like to hydro the boiler after an outage with extensive tube repairs and is throwing around the idea of using nitrogen instead of water. I have the volumes of water needed for each section, but am not sure how to convert this into the volume of nitrogen needed to perform the hydro...