Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. baba33

    Shell & Tube SIZING [tube velocity problem]

    HI SNORGY 0.21 ft/s is low because heat transfer resistance in Tube side, more than 75%. and also it is much lower than recommended tube velocity 2 ft/s. I can reduce number of tubes but with reducing NO. of TUBES, heat transfer area also will be reduced. And 0.5" tube diameter and tube...
  2. baba33

    Shell & Tube SIZING [tube velocity problem]

    Dear all I'm designing a shell & tube heat exchanger which it is supposed to be AES. and it should only be 1 in parallel and series. In periliminary design its sizes shell and Tube are 539-5500 mm respectively. and its tube count is 367 with 0.75" Diameter. And my design spec do'nt let me to...