  1. godel123

    SSV closing time

    thanks for all
  2. godel123

    protection curve but only a point (overcurent 51)

    how to "choose" the seting values to protect a motor, i mean is there a genral considerations or we have to make calculations? exemple of a motor : 50 Kw, 400 V.
  3. godel123

    protection curve but only a point (overcurent 51)

    hi overcurrent (51) protection. When we see 100 A 0.3 s. so why we talk about curve, but there is only a point
  4. godel123

    SSV closing time

    there is also a maximum velocity of the expansion of the spring when closing the valve, which is insured by limiting device in the control panel
  5. godel123

    SSV closing time

    Thank you for your answers. as we only have values ​​without Reference to any standard , i'm looking for a document that gives an explanation.
  6. godel123

    SSV closing time

    it's a hydraulic actuator the distance between the Christmas Tree and the control-panel is 50 meters
  7. godel123

    SSV closing time

    ssv : surface safety valve 15 s : is there a standard or is it a best practice or a company specification ?
  8. godel123

    SSV closing time

    hi What is the maximum time expected for SSV to close (by de-energize the hydraulic control of actuator) ?
  9. godel123

    CT magnetization

    indeed , passing a direct current will magnetize the CT.
  10. godel123

    power cable for motor with protection cable

    the earthing system (localy buried on field near motors) is not enough for desipation of fault?
  11. godel123

    power cable for motor with protection cable

    it's LV , 3phase +ground, the cable is armored the earthing system is every where aroud the motor location. i thought the use of the metallic armoris enough to use a torus.
  12. godel123

    CT magnetization

    if you inject DC==> no induction
  13. godel123

    power cable for motor with protection cable

    hi to feed a motor when should we use (exemple) 4g70 sqmm instead of 3x70?
  14. godel123

    standard about Air Tank Accumulators required for SDV or BDV

    hi is there a standard talking about the necessity to add an air tank accumulator for BDV or SDV?
  15. godel123

    dnv RP B401 understandind the use of coating deterioration factor

    hi the "fc" (coating deterioration factor) is used to find the final current density by using the formula : if = i *fc*A (where "if" is the final current density and "i" the initial value , A is the surface area). my ask is : initial current density is the value of bar surface ?
  16. godel123

    corrosion breakdown factor

    I am sorry to ask this question, but: what I do not understand is the value of the breakdown factor (in my sense) should produces a value bigger than 1 in a purpose to compensate the deterioretion of the coating by injecting more current!!!
  17. godel123

    DNV RPB401

    hi is the DNV RPB401 recommended practice used for offshore only or also for onshore cathodic protection design? I'm thinking about the Coating breakdown factor. Fc=a+b*t is there any sense to use it in underground structures evenly coated (bottom tank ).
  18. godel123

    Upstream power transformer for a 400 KW VFD

    it's in project, the VFD and the motor( multiphase pump) will be for rent and i don't really know the kind of VFD, but we have to prepare the project of supplying the substation.
  19. godel123

    Upstream power transformer for a 400 KW VFD

    hi all In Order to supply a VFD system (400 KW) we should install a power transformer (60 KV / 5.5 KV). my question is : is there special consideration about that transformer regarding to harmonics caused by the VFD ? thanks.