  1. Barow

    Difference between ASTM D2487 and D7928?

    Hello Gentlemen and ladies..... Haven't posted in a while and i searched the forum but couldn't find the answer, so i hope you'all don't mind my asking Pls what is the difference between ASTM D2487 and D7928? I'm thinking one is with determination of Organics (2487) and the other is without...
  2. Barow

    Heat transfer and heating up pipes/vessel question

    >>Not sure where you got the 20W solar load from; that's like 4 in the afternoon, hardly a peak sunlight condition, or an incredibly tiny surface area. The normally accepted peak solar load is at least 1 kW/m^2 Perhaps you should present some pictures, actual facts/data, etc. Your last statement...
  3. Barow

    Heat transfer and heating up pipes/vessel question

    Hello again guys: I'm having some difficulty with remembering some heat transfer concepts and I hope it is not an imposition to ask for a little bit of advise.I have a vessel or exposed pipe.... exposed to sunlight and the concern is that it can heat up to unacceptable conditions. I want to find...
  4. Barow

    Verifying grade of a pipeing material from old BOM/drawing

    Hi again Thanks so much for your help on this SNORGY. I'm just about done, but want to clarify the that I can hydrostatically test as part of the assembly, some items at say 10,000 kPa test pressure Gate Valve, 1", 600# - this one is fairly easy and i think the max it can be tested to is 1.5CWP...
  5. Barow

    Verifying grade of a pipeing material from old BOM/drawing

    Thanks very much SNORGY I'll use the pressure vessel formula's. I'll head to the office soon to get a head start and do this over the long weekend. I hope you don't mind if I post some more questions as i used the formulas and seek verifications. Basically, I need to hydrostatically test the...
  6. Barow

    Verifying grade of a pipeing material from old BOM/drawing

    Thanks very much Snorgy, From the drawings, its an end cap (closure). Its 400# tells me its PN68 and its size is NPS12 Yes, I think its grade must be 241 I will also need to calculate the hoop stress level in this end cap. I don`t think I can use the PD/2D formula since its not a pipe but an...
  7. Barow

    Verifying grade of a pipeing material from old BOM/drawing

    Hello Guys I've been registered on the forum for a while but have never really asked question. I hope I can get some help on piping materials verifications. Basically, I have an old drawings and want to verify the grade of the end closer which is described as - Hinged end closure 12” ASA -...