Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. SlurryPumps01

    Pump failure

    for me, it is not corrosion. corrosion will damage the whole case, not localized. i suggest to check the capacity and pressure, compare it with Performance Curve, check also NPSHa and NPSHr. Under capacity operation also should be consider. how old is the pump?
  2. SlurryPumps01

    Velocity vs. Discharge Piping Diameter

    for quartz sand, I will choose polyurethane
  3. SlurryPumps01

    Leakage - Twin Screw Pump

    Dear all, I install RUSCH twin screw pump, duty is Palm Oil Transfer Pumps, fitted with Mechanical Seal. The pump have product (palm oil) leakage on bearing housing, which I suspect cause by Mechanical Seal failure. However, the leakage stop if I run the pumps. Should I check the Mechanical...
  4. SlurryPumps01

    Southern Cross PSJ Series

    I have a problem when replacing a very old Southern Cross Pump PSJ Series. The old pump has a very special impeller as attached. Anyone can help me to give more information of attached impeller, and specifically of Southern Cross PSJ Series?
  5. SlurryPumps01

    Turing a non priming pump into a self priming/automatic priming pump

    Based on the figure; i suggest to have vacuum assist priming, you just need to have small vacuum pump or compressor. The controller will be much simple, just run the vacuum pump for a while (depends on the suction pipe volume and vacuum pump capacity) before run the main pump. Install a...
  6. SlurryPumps01

    Turing a non priming pump into a self priming/automatic priming pump

    The self priming system also will not work on leaked suction pipe. A small leak in the system, especially in suction side, will give big problem, no matter you use, self priming, or modified priming system, vacuum assist priming or just standard foot valve. Find good quality foot valve :)
  7. SlurryPumps01

    Turing a non priming pump into a self priming/automatic priming pump

    Have you consider to use a foot valve?
  8. SlurryPumps01

    Warman Pump Sleeve Failure

    I agree with all comments, but have you check the: 1. Stufing Box Condition (Inner Diameter) 2. Centre of your shaft compare to centre of stuffing box

Part and Inventory Search