  1. pukar12345

    CT Saturation calculation

    I have a CT with following data Ratio : 300:5 Class : C100 Burden : 0.1 ohm I don't have magnetisation curve for this CT. I want to calculate whether CT will saturate at fault current 3000A. Total Burden (Including CT secondary, CT leads and relay) is 0.45 ohm Excitation voltage (V) = (Fault...
  2. pukar12345

    Effect of higher frequencies on breaker and CT

    Hi All, I have a feeder feed by Variable Frequency Drive (VFD)of 60-200HZ. I have breaker and CT after VFD. Is there any effect on CT and breaker when frequency changes from 60 to 200hZ.
  3. pukar12345

    Over current relay for 50-200hz feeder

    Hi PHovanian / Davidbeach, Thank you for valueable inputs. I was in same line with you guys to use the in built protection of VFD but client was insisting to put extra protection. However, once you get 200Hz in your feeder,What is a problem to use WD5051 AC current sensing relays as suggested...
  4. pukar12345

    Over current relay for 50-200hz feeder

    Hi All, I have a feeder supplied from variable frequency drive (50 -200Hz). This feeder needs a overcurrent protection. But digital relays are not able to provide protection for varialbe frequencies (50-200)Hz. Is electro-mechanical relay suitable for variable frequencies ? Or what other...
  5. pukar12345

    CSA requirement for capacitor switching

    Is there any CSA requirement for the use of three independent pole breaker for capacitor and inductor switching to avoid trasients. I saw the use of independt pole breaker in 115 kv system for switching capacitor but not in 44kV system. Is there any CSA requirement ?
  6. pukar12345

    Standardized tests

    Hi ScootyUK, Thank you for your help I am practising phychometric tests in google and is quite helpful
  7. pukar12345

    Standardized tests

    I got a call for first evaluation from one of the north american utilities for technologist position in substation job. the evaluation process says a series of standardized tests to measure problem solving, mathematical and special reasoning skill. The test runs for 3 hours. Do anybody have...
  8. pukar12345

    CT accuracy

    Hi everyone, The CT has following tapping 1. X1-X4 3200-5 2. X1-X3 2400-5 3. X1-X2 1600-5 and if accuracy of CT is says 2.5L200@2400A what it means ? we get 2.5L200 accuracy when we use tap X1-X3 or we get 2.5L200 accuracy whenever primary current is 2400A irrespective of any tapping...
  9. pukar12345

    Maximum over voltage in four wire system with multiple ground points.

    Hi all, What is the maximum over voltage that could arise in four wire system with multiple ground points when system fauls occur (L-G or L-L of double line to fault or any other type) Thank you in advance for your reply.
  10. pukar12345

    Four wire system

    Hi all, In North America I saw four wire Transmission/distribution system for upto 27.6kV system. What is main purpose of neutral in such high voltage as all loads are three phase only in this voltage range. Thanks in advance for reply.
  11. pukar12345

    Short Circuit Rating

    Hi all, I saw the short circuit rating of a distribution system as following 1. for 27.6/16.0 kV 16kA 2. for 13.8/8.0 kV 34kA 3. for 2.4/4.16kV 56kA Why short circuit rating is higher when system voltage is small compare to higher system voltage ? Is not higher short circuit...
  12. pukar12345

    Selection of Lighting Arrester

    Hi everbody, what is basic rule for selecting lighting arrester for 13.8KV four wire system. Is there simple formula? Thanks in advance for reply.
  13. pukar12345

    four wire connection in delta system

    dpc Thank you very much for the clue. In which condition we can ground the primary side neutral ? Is there any related links, useful books? In my case, the Transformer is in substation and has mesh earthing. The primary side is coming from a transformer ( sytar/star with neutral ground)...
  14. pukar12345

    four wire connection in delta system

    Hi all, Hi everyone, I have voltage regulating transformer, 27.6kV/27.6Kv, Delta/ star. This transformer need to connect in 4 wire system both sides (Supply and load) I can connect 4 wire to star side of transformer. But in delta side of transformer where I should connect neutral wire...
  15. pukar12345

    Circuit switcher

    Hi all, What is a special function of circuit switcher ? It is different than circuit interrupter ?
  16. pukar12345

    Synchronous of reneable eneggy

    Hi all, I am looking some information on reneable eneggy. 1. How synchronous of inverter based generation is synchronized with grid ? it is same as synchronous generator with the help of synchronoscope or something else ? 2. What is common practise to connect solar power to grid ? I. PV...
  17. pukar12345

    Reneable wnergy to grid

    Hi Davidbeach, Thank you for the answer. Could you give me some guidelines in below. 1. Biogas, Biomass, Biofuel All these produce heat which boils water and generate steam that runs synchronous machine ? Please correct if I am wrong. 2. What is the reason for using Induction generator in...
  18. pukar12345

    Reneable wnergy to grid

    Hi Everyone, I have interest in renewable energy and would like to know how below renewable enery connects to grid 1. Solar PV cells 2. Bio mass, biogas, biofuel 3. Wind 4. tidal I believe solar PV cell produce DC power, then it converts to Ac by inverters and so on. And more related to the...
  19. pukar12345

    Breaker Failure Initiate

    Hi everyone, Can anyone explain me how BREAKER FAILUR INITIATE works ? I have a scheme having Bus bar with 3 outgoing feeder and 1 incoming feeder. If outgoing 1 fails to trip, then Breaker failure relay at outgoing feeder 1 sends trip signal to trip outgoing feeder 2, outgoing feeder 3 and...
  20. pukar12345

    Neutral in Automatic Transfer Switch

    I saw automatic transfer switch with 4 pole where neutral of both source connected to one pole of switch and neutral of both switch never mixed. I saw automatic transfer switch with 3 pole where 3 phases are connected to 3 poles and neutral is connected to common neutral bus. In this case...