  1. hayden2009

    Screw Compressor OIL

    Yes, mixes and seperates in the lube oil seperator. Attached is the MSDS for the oil.
  2. hayden2009

    Screw Compressor OIL

    What viscocity for oil would be required for a propane refrigeration system. We have 2 2500HP, and 1 300HP Howden Compressors packaged by Toromont. The refrigeration propane charge is less 1% ethane, bone dry -40. We are experiencing problems on the 300HP Compressor. It is requiring 2 oil pumps...
  3. hayden2009

    Refrigeration Scrubber Vessell

    For a propane refrigeration loop,the Scrubber Vessel has a data plate in which is states the vessel is rated for -55 F. The outlet flange is a A 105. The flanges as well as the scrubber will see temperatures as low as -50. Shouldnt the flange be A350 for cold service?