  1. metta0810

    Thermal Resistivity and Underground Cable Sizing

    I'm sizing the underground cable in direct buried conduits with 2 x 8 arrangement using ETAP software.The thermal resistivity (RHO) based on the geotechnical report indicates around 40 cm degC/Watts which is considered very low. The IEEE 835, and NEC basically list the soil RHO at 60, 90 , and...
  2. metta0810

    B Phase CT on the Load Side , A & C Phase CT on the line side of bkr

    Dear all, Does anyone know why A and C Phase CT located on the line side of the main breaker (Polarity towards the top of the breaker) and the B Phase CT located on the load side of the main breaker (polarity towards the bottom of the breaker)? I've never seen this application before. Please...
  3. metta0810

    Local Disconnect Switch for 13.8kV -208Y/120V transformer required?

    I'm working on a project where we need to install a 13.8kV-208Y/120V Transformer to feed non-rotating distribution loads. The Transformer is being fed from a remote source (located about 300 ft away) which has a breaker. Do I need to provide a local disconnect switch on the primary side of the...
  4. metta0810

    California Electrical Code and Halogen Free Cable

    Thank you for your very helpful answer
  5. metta0810

    California Electrical Code and Halogen Free Cable

    Does California require for Halogen Free Cable on particular cable installation?
  6. metta0810

    three-single phase transformer impedance

    Thank you all for your answers.
  7. metta0810

    three-single phase transformer impedance

    Attached is the transformer name platehttp://files.engineering.com/getfile.aspx?folder=d8dbcb1e-ab69-40a4-a773-363a3cabb0fc&file=100_6301.JPG
  8. metta0810

    three-single phase transformer impedance

    I have three-single phase transformer, each is rated at 250kVA, 34500-2404x7212/12490Y. The name plate shows if the secondary side is connected in series the voltage is 7212V, 34.7Amps. If the secondary is connected in parallel the voltage is 2404V, 104 amps. The impedance shows as 5.15% at...
  9. metta0810

    480/277V supplies 480-480/277V Lighting transformer

    Alehman, The two 500 kVA Transformers are supplied by two separate 4.16 kV buses. The transformers feed the MCC through a three pole transfer switch (not a separate derived system). Therefore, grounding the neutral at the upstream main disconnect are not required in accordance with NEC 250.20...
  10. metta0810

    480/277V supplies 480-480/277V Lighting transformer

    Dear Friends, Thank you all for your responses. I should've clarified from the beginning that the term "Lighting MCC" is the MCC for Lighting Loads purposes.
  11. metta0810

    480/277V supplies 480-480/277V Lighting transformer

    Dear friends, I have two 500 kVA Lighting transformers (4160V Delta - 480/277V Wye) coming through a three pole transfer switch to feed a 480V Lighting MCC. The transformer neutral is terminated at the MCC ground Bus. Is it allowed to supply a 480-480/277V lighting transformer from the 480V...
  12. metta0810

    Exception cable space requirement in cable tray

    Thank you for all the replies. I really appreciate it.
  13. metta0810

    Exception cable space requirement in cable tray

    I use 2kV (client's requirement) 3/C-500 kcmil w/gnd (4 cond/phase) which runs 916 ft to feed 800Amps Bus in Motor Control Center. The cables are oversized to avoid the excess voltage drop especially during the motor starting. These cables run through a 36" multi lay cable tray. I calculate the...