Thank you all, most helpfull.
The thermal fatigue as required by the code was calculated in our case, but does not seem to address the rate of heating or cooling. Or have I missed it? How significant is it?
UCS-56 d,2 eg states a heating rate of 400deg F per hour per inch thickness, for above...