BS4994 requires pvc lining of GRP tanks to be radiused at intersection between tank wall and floor.
With a sloping base(floor) it is very difficult to fabricate such a radius on pvc liner.
One fabricator overcomes this difficulty by providing square edge (shell to base) configuration.
Does...