Many of you, I am sure, use Von Mises as a yield criterion to calculate the equivalent stress and strain on your system. I am using Hill 1948 as it provides an anisotropic analysis. However, I am having trouble calibrating Hill48 using the r-values.
Hill constants F,G,H are requal to r0, r90...