  1. Dogma72

    convective flow

    well in that case i'm sorry that i asked the question in the first place. although, i really don't see where the big hang up is - i'd really rather have that explained to me rather telling me that i'm living in some kind of lala land. That is completely unhelpful. cold water falls, pushes...
  2. Dogma72

    convective flow

    I tend to disagree. You can remove 7% of a nuclear reactors power output through natural circulation and that is without an obscene difference in height. Granted you are not using mechanical energy to spin a turbine. But, that is more an issue of designing the system to minimize head loss and...
  3. Dogma72

    convective flow

    perfect. Thanks a bunch. BTW, I'm assuming that there is a general design guideline for sizing pipes vs. volumetric flow rate. In my scenario, I want to minimize head loss so, I would want to oversize everything to the extent practical from a cost standpoint as to minimize non-useful energy...
  4. Dogma72

    convective flow

    So, How would the difference in height affect the differential pressure? density is usually in kg/m^3 or lb/ft^3 pressure is psi or metric equivalent so, if the cold leg is something like 980 kg/m^3 and is at 25ft in the air and the hot leg is 900 kg/m^3 and is at 0 ft relative elevation...
  5. Dogma72

    convective flow

    I don't believe there are any commercial solar panels out there that are designed to do what i want to do. Basically the issue with solar panels is that they are only 10 to 15 percent efficient. Whereas a water turbine is upwards of 70 percent and as long as i can minimize heat loss through...
  6. Dogma72

    convective flow

    the other thing that i'm noticing while reading through this is that the focus is primarily on heat transfer. In my applicatioon, i really do not care about that. What i care about is the fluid flow, in gallons per minute, based upon an experimentally determined rate of heat input. i.e. if i...
  7. Dogma72

    convective flow

    Basically what i want is something that i can just plug and chug into. I want to essentially have water/ethylene glycol mixture 30 ft x 10ft x .25 inch solar panel. I want to have a 25 or 30 ft high vertical pipe connected to it, where it would flow upwards into a heat exchanger and then...
  8. Dogma72

    convective flow

    hey, thank you very much! When I was clicking the link, i thought for sure i was going to some place where i could purchase the appropriate text - i was super excited when i saw that i could just download the thing! Awesome help! I'll be back though if i need some clarification! Wes
  9. Dogma72

    convective flow

    Hi, I'm working on designing a natural circulation system. I'm hoping for some help. I need some help determining flow rate based upon differential temperature and also calculating what pressures will exist at various points in the system. Thanks a ton Wes