Hi all,
Actually this is the first time I'm dealing with BS&W Analyzer in Desalting Packages. As far as I could find, two different types are available. One measures only the BS&W on-line and salt shall be examined in Lab.
The other one measures salt content online as well as BS&W.
I wonder if...
Dear Prochem
BS&W is usually reffered to volumetic flow percentage of water @ STD condition.
Insoluble water is the total amount of water ( excluding solved portion ) in your crude but in Act. Flow.
Free water is reffered to that portion of water you can seperate in seperators and etc. one...
Hi all,
Actually this is the first time I'm dealing with BS&W Analyzer in Desalting Packages. As far as I could find, two different types are available. One measures only the BS&W on-line and salt shall be examined in Lab.
The other one measures salt content online as well as BS&W.
I wonder if...
Hi all,
actually almost every body disappointed me. I'm still waiting for Herion and Parker. Therefore, I would appreciate if you inform me about any other manufacturer if you remembered s.th
Regards and thank you all
Salar
Hi everybody,
for some of our projects in Canada, I need explosion proof solenoid valves, with Manual reset/ Position switches option. I would appreciate if anybody shares his experience with any manufacturer since I'm in trouble to find manufacturer.
Thank you so much
Regards
Salar
Hi everybody;
Actually this is the first time I'm making myself involved with selection of insulation (material & thickness) for piping and vessels. I wonder if there is any code or spec that recommends some criteria. I would appreciate if someone introduces/shares any related design code...
Hi all;
Has anybody ever been involved with desalting package for live oils ( GOR about 100 scf/sbbl )?
what are the major concerns of having dissolved gas ? Besides, I have read somewhere that having electrostatic filed can increase the potential of making disslved gas, free. Does it make...
Hi all;
Has anybody ever been involved with desalting package for live oils ( GOR about 100 scf/sbbl )?
what are the major concerns of having dissolved gas ? Besides, I have read somewhere that having electrostatic filed can increase the potential of making disslved gas, free. Does it make...
Dear Prochem,
Thank you so much for your kind advice. I tried to review ASME sec 8, and I will review API 520 and API 521.
Actually I'm not that much experience to design a whole package alone, and I always receive advice of my supervisor on these critical issues. However, I would like to know...
Dear Pleckner
Thank you so much for your answer, I think I have some general Idea now, and I will read API 521 and API 520 , and then, ask my questions again,
Regards
Salar
Dear Mortena
Thanks a lot for the references, but before reading API standards, I would like to make sure the purpose of having PRV on processes. As far as I know, only one reason can be Fire, while on pressure vessels, instead of considering Fire cases, we usually consider PRV with the...
Hi all,
Having similar projects, I'm totally confused with the required capacity of pressure relief valves on the top of Desalters, on previous projects, I have considered the required capacity to be equal to the inlet to the desalter regardless of thinking about fire case. Can you please tell...
Hi everybody,
I'm a lttle bit confused with purpose of having Pressure Relief Valves on different points and i'm full of different questions in my mind. i appreciate recieving your technical helps.
On top of pressure vessels, we almost always consider PRV, which prevents from over pressurizing...