thanks for the reply...
@fegendush
the corrosion allowance is applied on both sides (1.5mm each on in/out). Crown radius is specified on client drawings so i intend to follow.
@c8829
yes, i already uncheck the intepretation. I checked compress support center and verified that supplementary...
Hi guys, need some advice.
I have this internal torispherical (F&D) head with the following dimensions;
1100 O.D
Crown Radius = 1100
Knuckle Radius = 110
Corrosion allowance = 1.5mm on both sides
i tried running in Compress but the program prompts this deficiency message,
" UG-32(j): The...