Hello All!
I am tasked to do cross-references between ASME PCC-2 and API 510. I have questions regarging article 8.1.6.1.4 in API 510.
1- Could anyone show me an exemple or explain what are nonpenetrating nozzles?
2- Is this classified as a temporary or a permanent repair? I`m confused as...
This is what I believe as well. However they say they will not reach 450 psi at high gauge because they will exceed the flange rating pf A105 Class 150 flange. I do agree they should not exceed the 450 psi. My point is that in this case they should test the length on pipe in 2 or more sections...
Here is a question about B31.3 Hydrostatic Test.
LDT Test Pressure is 450 psi
DP: 275 psi
CL 150# rated fittings
Test relief valve set at
During the leak test, the low point gauge was reading 450 psi as per LDT required test pressure. High point gauge (about 80-100ft up) was reading 400 psi...