Beggs-Brill is good for calculating the pressure drop in cross country pipeline/flowline having diameter 8 inch or less.For small pipe lengths (e.g. inplant piping) and where the total pressure drop is less than 10% of the inlet pressure, API-14 E equation gives the better results.
Beggs-Brill is good for only for cross country pipeline/flowline having diameter 8 inch or less.For small lengths (e.g. inplant piping) and where the total pressure drop is less than 10% of the inlet pressure, API-14 E equation gives the better results.