  • Users: obg
  • Order by date
  1. obg

    Loadcell readngs help please.

    There is an offset on the INA25 that does not correspond to the load cell off-set. In order to make sense of the INA output you must determine this value. The load cell o/p is good when zero corrected. Check out for the commomn mode values on the INA125 I seem to remember an issue with this. OBG
  2. obg

    Noise attenuation due to elbows in ducts

    I don't think you will get a simple answer to this one. Mitre(rectangular) bends are frequently equiped with internal turning vanes. The number and size of these will determine the airflow resistance of the bend - which will inturn change the amount of re-generated noise. Most people will just...
  3. obg

    Difference between pressure transmitter and transducer

    Wow a promotional campaign! As I said at the beginning it has gotten rather confused. In Pure terms a transducer converts one form of energy to another, whilst a transmitter does what it says (sends out signals). However if you have a sensor of any type (or brand) it will have to contain both...
  4. obg

    Difference between pressure transmitter and transducer

    As a general rule of thumb they both do the same thing. However some manufacturers call a current output type ie 4-20ma a transmitter and the voltage output types ie 0-5v a transducer. As a guide most users use transmitters with cable runs of 10metres and over.
  5. obg

    vibration/octave band center frequency

    Look at it as bite of frequency as opposed to a single variable. Its just a way of simplifying the number of measurements. So treat it as Hertz.
  6. obg

    4-20 mA Shielding

    Just a thought 400 ohm @20mA =8v from a 12v supply are you sure your sensor can work from 4v - the losses in the cable. you may be on the wrong track with the rfi issue.
  7. obg

    CONTAMINATION CODES

    Hi, Making sense of fluid contamination monitoring can be a real can of worms. I am aware of two guy's that have been involved in this for several years who would most likely be able to answer your questions, as they do this for a living. I can only give you a phone number and and their names:-...
  8. obg

    led flasher with normally closed switch

    Assuming you have a ballast resistor for the LED you could simply connect your switch across the LED ie normally closed = shorted out, open switch = flashing LED
  9. obg

    Saturation point of water in hydraulic oil

    I am attempting to predict the change of saturation level of Hydraulic oil, with respect to temperature. I have a device that will give me the percentage saturation level over a thermal range of 10 - 70Cº but cannot as yet translate this into PPM.
  10. obg

    Saturation point of water in hydraulic oil

    Does anyone know of a method of predicting the ppm saturation point (water absorbed in oil) with respect to temperature.