  1. thalathb

    Field pressure and temperature gauges

    It always nice to have such bach-up to your DCS readings...Never rely on one source..
  2. thalathb

    closed condensate drain drum

    Do you think the sand is used as a medium for cathodic protection electrons to move throw??
  3. thalathb

    closed condensate drain drum

    Chance17, This sand is located outside of the vessel, covered the entire vessel. I dont see any filteration process going on here.
  4. thalathb

    closed condensate drain drum

    Ione, The answer is no.
  5. thalathb

    closed condensate drain drum

    Quark, Thanks for your reply. I dont think the sand is there to support the expansion as this vessel is underground. If that the case they would desgin it above ground. Thanks again
  6. thalathb

    closed condensate drain drum

    Hi, There is a closed drain drum for condensate system which is an underground vessel and covered by concrete. This vessel is buried with sand and under cathodic protection (CP). Question: What do we need the sand for? Can I remove the sand? Thanks in Advance for all of you.
  7. thalathb

    shutdown and startup

    I think you should decide first about making those pumps an Auto start or manual. I will try to get you much details about shutdown procedure.
  8. thalathb

    check valves

    some times it installed in series for economic reasons, like two small check valves in stead of a huge big one. some time it depends on the pipe rating as well, (900# vs 300#)
  9. thalathb

    Crygonic Draining

    Hi every body, Does any one have any experience of "Crygonic Draining system" and how it works. I have a Crygonic system and I must to design a draining system for it!!!?
  10. thalathb

    Technical Evaluation

    Dear All, I'm reviewing two technical proposals from 2 bidders, and I'm suppose to do final techincal evaluation in order to help my boss to take his decision easly, what am i suppose to show in this, is there any typical format? Thanks
  11. thalathb

    Columns with two diameters

    Hi every body, Regarding the distilation cloumns, Why most of the demethanser and Deethanizer has two diameters, for exampel the de-ethanizer has bigger diameter at the bottom and smaller one at the top, vise versa for De-c1. Thanks and regards
  12. thalathb

    Vaporization Propane without LPG vaporizer

    Why dont you design the tank as per the normal consumption, and let the vapour vent up thorught compressor , then gets condensation in the way back to tank as liqued again.
  13. thalathb

    Operating & Control

    Hi all, Whats “operating and Control philosophy” documents on sales gas project or in general must describe? I appreciate your thoughts. Regards
  14. thalathb

    Where is the prefered location of thermal relief valve on S&T HEX

    Both are acceptable, but make sure all the valves on pipe are CSO.
  15. thalathb

    Isolation procedures question

    I dont think there is a specfic stander or code will give you a sufcient material for DBB, each company has its own isolation procedures for using double block and bleed valves.
  16. thalathb

    Sour water material selection

    Dear all, What is the proper material to be used for sour water vessels? currently our contractor is suggesting KCS+3mm 316L ss clad, or should we use SS? Thanks in Advance.
  17. thalathb

    Bypass or Hand jack

    Thanks all for your inputs.
  18. thalathb

    Bypass or Hand jack

    does any one have tips or criteria to help for designing the Valves with bypass or Hand jack rather than criticality?
  19. thalathb

    Auto start Pumps

    Hi All, Could any one provide help for this matter please, What are the main systems I could not use Auto start pumps or not recomended. Thanks and Regards TH
  20. thalathb

    Bypass or Hand jack

    Gents, I know the system criticality plays a big roll here to design the valve with Bypass or Hand jack. But, does any one have tips or criteria to help for designing the Valves with bypass or Hand jack? Thanks and Regards TH