Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. 786392

    Effect of Sudden Pressure on Piping System

    Dear bonzci, Are we 100% sure through master pressure guage& pressure checked and/or recorded at different points of "the piping segment under pressure test" as regards sudden pressure shoot up from 0 to 100%? Was this a pressurizing with high pressure rotary or positive displacement piston...
  2. 786392

    furnace tube bluged

    Though agree fully with 25362& weldstan. But please do check /analyze data of crude flow through the tube as if for any reasons minimum cooling media flow was not ensured at all times through operation(by mistake or intentionally; which usually results in starvation/ localized hot spots)...
  3. 786392

    Pipeline Pig Stuck

    Dear adtw777, Hello/ Good Day, Though very much belated reply but may be helpful; at times there exist minor dents in the piping, even in some fittings(e.g. ell's etc.) accordingly cups inversion could have been due to this and final outcome appearing as few inverted cups& a finger stuck at...
  4. 786392

    Pump keeps kicking out

    Moreover "Just a wild thought" We should check for and eradicate any possibility of physical obstructing material as if being sucked-in at random intervals thus affecting pump out operations with increased E/power demand. Best Regards Qalander(Chem)
  5. 786392

    Safe Distance For manually Operated Fire hydrants Foam/Water Monitors Above ground Fire Water system

    Hello/Thanks David It was nice guidance and should lead me better focused on the issue under research/discussion. Really grateful Best Regards Qalander(Chem)
  6. 786392

    Safe Distance For manually Operated Fire hydrants Foam/Water Monitors Above ground Fire Water system

    Thanks Stookey, So, it isn't all that important if these equipment have been placed by the design and construction people right in the midst of plant! Crowded by hydrocarbon containing equipment/pipelines etc??? Can a flag be raised referring any code/standard's clause for needful...
  7. 786392

    Safe Distance For manually Operated Fire hydrants Foam/Water Monitors Above ground Fire Water system

    Dear All, I have always understood and Considered a minimum of 15 Meter or 50 Ft distance as mandatory 'Keep away" for safe operation and accessibility for Fire fighting in Oil refineries, Petrochemical Plants. Please guide if this is OK, or Incorrect with kind reference please! Thanks in...
  8. 786392

    Safety Shower and Eyewash Philosophy

    Some more links http://www.stanford.edu/dept/EHS/prod/mainrencon/Labdesign/Section_1-2_Safety_Eyewash_Showers.pdf http://www.ehs.unr.edu/Documents/Eyewash-ShowerStations.pdf http://www.professionalequipment.com/guide-to-eyewash-shower-reqs/articles/ Best Regards Qalander(Chem)
  9. 786392

    Safety Shower and Eyewash Philosophy

    Dear, Probably this replies your querry http://www.grainger.com/Grainger/static/emergency-shower-eye-wash-station-requirements-120.html Best Regards Qalander(Chem)
  10. 786392

    Free water content in heavy fuel oil

    For a heavy fuel oil having higher viscosity we may anticipate settling out faster in case storage temperature stays around 80-85 celcius. But should be around 2 days I assume. Best Regards Qalander(Chem)
  11. 786392

    Free water content in heavy fuel oil

    Dear, Somehow I am of the opinion that if any mixing is affected in these tanks for homogeneous intake for pumps and indirectly supporting uniform calorific value. Then the water/water vapors are bound to find their way into the storage tank's vapor space. Having said that,it is also a plausible...
  12. 786392

    Process question

    Dear IngGasP Hello/Good Afternoon, why don't you google I got the results many http://www.standard.no/pagefiles/1134/p-001e5.pdf http://www.schuf.com/download/Valve%20News%20Line%20Blinds.pdf http://www.pdhcenter.com/courses/m182/Process%20Design%20P-001.pdf...
  13. 786392

    4130 with SS E316L-17 Overlay without PWHT?

    Dear metengr, Hello/Good Morning, I like that!! Best Regards Qalander(Chem)
  14. 786392

    Sending vapor line to liquid line

    Still as Latexman said P&ID is a must. To correctly analyze,guide/attempt for problem resolution with particular details e.g. Where is the subject liquid pipeline's routing/final termination point i.e. going through some vaporiser to flare system or elsewhere?? Best Regards Qalander(Chem)
  15. 786392

    Drying an Internal Floating Roof Tank

    Just a wild thought some desiccant material under the roof with dry Nitrogen blanket might be an answer but may prove very expensive! Best Regards Qalander(Chem)
  16. 786392

    Pipeline Size and Pressure relation

    And, Also the "maximum possible shut-off pressure may it be exposed to!!! Best Regards Qalander(Chem)
  17. 786392

    Deionized Water from Air conditioner

    Dear, Agreeable, subject to due filtration for mold,filth& dirt etc. removal. Then with needful disinfectants addition indeed! Best Regards Qalander(Chem)
  18. 786392

    Relief valve - releasing oil back to the sump or to the pump suction line

    But, caution is needed in avoiding direct impact on to the sump; causing erosion in any way! Best Regards Qalander(Chem)
  19. 786392

    Deionized Water from Air conditioner

    No,It is my personal opinion that unless and until the complete route,consing environment& the container receiving are free of any salts or ionic contaminants. It may be called fairly low T.D.S.& electrolyte containing water (as it is from water vapors re-condensation; but not absolutely...
  20. 786392

    sealant to be used in conjunction with fibreglass tape bubble cap tray gasket to pass leak test

    Dear, Does not seems a practicable idea since the temperature and processed materials environment will not permit these to stay in-place for long! The temporary sealing will be very soon ruined and damaged/dislodged as per point turbulence conditions; most frequently occurring at the bubble...

Part and Inventory Search