Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: sundy
  • Order by date
  1. sundy

    Long-term deflection=three times dead Plus one time live

    Please read the papers(pdf format)I post above, it references ACI318-2000. Why?
  2. sundy

    Long-term deflection=three times dead Plus one time live

    I post the paper here. See page 273 equation(12)http://files.engineering.com/getfile.aspx?folder=6dd5b860-075f-4bfb-a2f7-924f25f36875&file=Effects_of_creep_and_shrinkage_on_the_deflection_of_RCC_two_way_flat_plates.pdf
  3. sundy

    Long-term deflection=three times dead Plus one time live

    Thanks,asixth Please include the factors "LF_short","lamba" and "LF_long".
  4. sundy

    Long-term deflection=three times dead Plus one time live

    asixth: Could you provide any references for the caculations: 1. Short-term displacements... delta_short=G+0.7*Q 2. Long-term displacments... delta_long=(1+kcs)*G+(1+kcs)*0.4*Q Especially, for "delta_long=(1+kcs)*G+(1+kcs)*0.4*Q"? Thanks a lot.
  5. sundy

    Long-term deflection=three times dead Plus one time live

    I have come across a papers (“Effects of creep and shrinkage on the deflection of RCC two way flat plates”) which states that, in ACI 318-2000, the total deflection of two-way slab for the creep and shrinkage effect is calculated as three times the deflection due to dead and deflection due to...
  6. sundy

    RX and RY Modal Participation Factor

    How to calculate RX and RY Modal Participation Factors. See the attached picture.
  7. sundy

    Column Base Plate Grout Chamfer

    structuresguy Please see the attached file. File's link is: http://files.engineering.com/getfile.aspx?folder=8ad87dfa-f5df-424a-819c-c555345ad514&file=Probleme_1_p.90.pdf Shoulder edges(as you usually do)would lead to crack. Please comment on this.
  8. sundy

    Column Base Plate Grout Chamfer

    When the forms set tight to 3 sides,and a small gap on the fourth to pour in the grout, how to ensure that the air underneath the base plate can effectively get pushed out when grout gets in from the fourth side? I have read some grout installation instructions,which indicates that no air should...
  9. sundy

    Column Base Plate Grout Chamfer

    structuresguy, Thanks for your replies. As you say,you have very rarely seen actually chamfered grout pads,and you pointed out in the next reply, "If it were not chamfered away from the plate, then the edges of the grout could easily crack due to be unconfined." The question: Have you seen...
  10. sundy

    Column Base Plate Grout Chamfer

    The column base plate grout usually needs to be chamfered 45-degree around the edges. When does the guy on site do the chamfering? (The forms for the grouting have chamfer strips? or the edges of the grout chamfered after the forms removed?) What kind of tool does the guy on site use in...
  11. sundy

    Sag rod "double nutting"

    Girt Bracing Question 08/01/2007 I am designing a building with vertical siding, channel girts, and sag rods. I was told that the industry standard is to consider the channel braced at the sag rods. How is this possible, since the sag rods are neither at the compression flange nor able to...
  12. sundy

    Pages of SDI DDM02 Example 7g

    pages number of "SDI DDM02 Example 7g"
  13. sundy

    Pages of SDI DDM02 Example 7g

    I would like to order a copy of "SDI DDM02 Example 7g" from Linda Hall Library, who can let me know the pages of this example. Thanks.
  14. sundy

    At the one-third points

    CSA S16-2001 19.1.5 For starred angle compression members interconnected at least at the one-third points, Clause 19.1.4 need not apply. What does the one-third points refer to here? Thanks in advance.
  15. sundy

    "taken as unityö and ôtaken as 1ö?

    Load and Resistance Factor Design Specification for Steel Hollow Structural Sections November 10, 2000 4.1.1(c)In frames for which lateral stability is provided by diagonal bracing, shear walls or equivalent means, K shall be taken as unity, unless a lesser value can be justified by rational...
  16. sundy

    out of plane strength check and K factor

    CSA-S16(Canadian)applies notional load for in-plane strength analysis. A structure: moment resisting frames in both X & Y directions as lateral system. When notional load in X direction applied in analysis to check in-plane strength,K factor is taken as 1. Can the moment resisting frame in X...
  17. sundy

    Etabs Steel Gravity Interactive Design(Shear Wall as Lateral)

    I have an Etabs model(Canadian Code) with shear wall as lateral and steel framing(Pin-Pin connection) as gravity. After I design/check the steel members, I am able to go into the steel interactive design window. However,some of the beams are not active(wouldn't allow you to select them to get...
  18. sundy

    Precast Wall Panel Connected to Steel Frame

    I have seen an ongoing project in Toronto using precast wall panels as cladding connected to steel frame. The connection uses a kind of spacers which are new to me.It seems like transparent plastic material. Would anybody familiar with this give any clues about what material it is? And how do...
  19. sundy

    Look for "Lateral Resistance of Piles in Cohesive(cohesionless) Soils"

    First of all, thanks, jdonville. I made a search in Linda Hall Library database, but did not find the desired articles. See if you could find it and let me know.
  20. sundy

    Look for "Lateral Resistance of Piles in Cohesive(cohesionless) Soils"

    Hi, could anybody give me any tips on how I can buy the following two articles? Broms, BB 1964 "Lateral Resistance of Piles in Cohesive Soils", ASCE Journal of Soil Mechanics and Foundation. Division, Vol. 90, No. SM2 Broms, BB 1964, "Lateral resistance of piles in cohesionless soils", ASCE...

Part and Inventory Search