    Driven 1.2 Software

    Is there a 64-bit compatible software that determines ultimate vertical static pile capacity using FHWA methods similar to Driven 1.2? The closed thread, thread274-174559, led me to UniPile which stated that it uses the Fellenuis Unified Method. Are there any others? Thanks in advance.
  2. Stoph

    Bleeding Effect during Proctor Testing

    Snagglespree, we encounter this often when we test ODOT #304 (a well-graded granular base material). While I believe that this type material should only be tested with a roller pass test section, we still provide a starting optimum moisture content to the contractor using AASHTO T-99. I have...
  3. Stoph

    How to get Shelby Sample into a 2.5 inch Direct Shear or Consolidation

    Acker Drill company has the 2 1/2" OD size and others. We've used them for years. www.ackerdrill.com
  4. Stoph

    Cement bentonite grout mix

    Here is a link to an excellent paper on this topic. Unfortunately, here in Ohio, we cannot use sand backfill due to groundwater quality policies on sealing a borehole. http://www.slopeindicator.com/pdf/papers/grout-backfill.pdf
  5. Stoph

    ?hydrometer analysis

    Your mixture sounds correct. But I think what IANDIG was referring to is the fact that you only use 50 mL of the 40 g/L sodium hex mixture per cylinder. The rest is either deionzied or distilled water.
  6. Stoph

    CUTX Consolidation

    However, the spec says to take readings at different time intervals, not just the initial.
  7. Stoph

    CUTX Consolidation

    ASTM D 4767-04 under section 8.3.3 During the consolidation phase the spec says to "record the accompanying deformation indicator readings by carefully bringing the piston in contact with the specimen cap." With 60 to 80 psi cell pressure, it takes all the strength I can muster to push down...
  8. Stoph

    Moisture-density curve for clean sand

    I would agree with the "let it bleed" option if the water were clear, but this bleed water is typically not which means that the few fines that you do have in these materials are washing out with each successive test point. So the material changes, which is a change in specific gravity, which...
  9. Stoph

    Moisture-density curve for clean sand

    While I agree with DGillette completely, some agencies still require standard proctor on these poorly graded sands and gravels when used as fill or backfill. To deal with the bleeding between the bottom of the mold and the base plate, I use a little vacuum grease around the base of the mold...
  10. Stoph

    Geotechnical Lab Database

    http://www.gintsoftware.com/
  11. Stoph

    direct shear test - standard loading

    ASTM D 3080...The loading depends on the consolidation pressure needed to simulate field conditions, and the specimen size varies based on the maximum particle size in the sample. See the ASTM (or in my DOT case AASHTO T-236) for details.
  12. Stoph

    failing compaction efforts in silty/sandy material

    I have occasionally seen the Sand Cone called a Wet Density method, but it doesn't sound like this what they are referring to in this case.
  13. Stoph

    One Dimentional Consol AASHTO T216 / ASTM D2435

    AASHTO T-216, Section 6.1 Load Device says "...should permit quick application of a given load increment without significant impact." AMRL must be assuming that a screw arm is the only way to accomplish this because their own inspection worksheet only states that Load Device "permits quick...
  14. Stoph

    TN changes education requirements for the PE to include masters degree

    Ohio requires 8 years experience with a Engineering Technology degree.
  15. Stoph

    LOI testing of Top Soil

    http://www.dot.state.oh.us/construction/OCA/Specs/SSandPN2005/10160402for2005.pdf See above link for the specification in question. Does anyone know what purpose the ammonium carbonate serves in this instance? I have ran Organic samples in a muffle furnace per AASHTO T-267, which uses a lower...
  16. Stoph

    ADAS for triax (CU,UU), 1d consol

    We recently upgraded from DS6 to DS7. My only issues so far are that calibrations must be done in SI units, and raw data is only written in SI units to an ini file. As far as customization, it seems they follow AASHTO/ASTM/BS pretty strictly, but you do have the ability to create a...
  17. Stoph

    Desiccators and desiccants

    https://www1.fishersci.com/ A clever person solves a problem. A wise person avoids it...Einstein
  18. Stoph

    April 2006 Transportation Depth PE Exam

    http://www.ncees.org/exams/professional/pe_design_standards/transportation_design_standards_06.pdf This link lists the current standards as listed by bear26.
  19. Stoph

    weak rock

    I thought for sure you would have come up with the Nitty Gritty Dirt Band. [thumbsup2] Stoph
  20. Stoph

    Aluminum Inclinometer Casing?

    It also sounds like they are implying corrosion issues with long-term aluminum inclinometer installations.