We once replaced a bitumen-lined Ductile Iron sewage rising main which, after 25 years use, was riddled with holes along its invert as a result of ineffective grit separation at the inlet works.
Here in the UK, D.I. pipe for sewage applications now comes lined with High Alumina Cement, which is...