Hi dbill74,
The bleed system or pneumatic system is a supplier system that provides air in a certain temperature and pressure depending upon the consumers needs - air conditioning, engine starting, anti-ice. Therefore, the flow, pressure and temperature would depend on your application - based...
Hi DHambley
The failed item is a tie rod - even though it did not break, the soft mount at its end cracked - this was noted due to the shift on the ressonance search at the end of the testing for one axis.
Thanks,
Hi IRstuff
Thanks for your reply. I understand your position and fully agree with you - failure of the attachment points indicates design issues and needs to be resolved. Thanks again
Thanks for all your reply.
I agree with IRstuff that the failure of the attachment point is a matter of concern - however, RTCA DO-160 is applicable to equipments and not structural elements. Therefore, my concern now is to validate that equipment will pass on vibration testing - verification...
Hi folks,
Do you know if failure of attachment point (representative of actual installation and used to fix the equipment under testing) during Rtca DO160 Vibration testing is considered acceptable (attachment point can be replaced and testing can be resumed)or it constitutes a failure to meet...