  1. jb66

    Problem with printer

    Hi, could give me anyone an advise where to get driver for printer Canon BJC 5500 for WinXP? Thanks. jb66
  2. jb66

    Contraction joints in slab

    Thanks to all, I agree with jike - the best solution is probably compromise between two points - slab-on-grade and topping without control joints. The topping will be bonded to the precast slab but not too thickly. jb66
  3. jb66

    Contraction joints in slab

    I have to design storage building with 4 floors, 100x100´ (lxw), 85´height with using of prefabricated concrete elements. The posts and girders are in 20´x20´grid, ceilings could be from prestressed hollow panels (thickness 12´´) with concrete slab (membrane) (th. 3,5´´) on the top of the...
  4. jb66

    Unheated Building with Slab-on-Grade

    JAE ... yes, I thought thickened slab strips, sorry for my english. These strips could be in spacing cca 8´x 8´, 12´´ deep and 6´´ wide. If the slab would be reinforced with mat near of upper surface and the "ribs" as well (it is enough one strip of the mat vertical in the middle ), so I...
  5. jb66

    Unheated Building with Slab-on-Grade

    I think that is better to use granular fill which depth depends on quality of subsoil and the slab reinforce by ribs (my experience). If the internal construction of swimming pool is sensitive to heaving it is necessary to solve very well dilatation between floor slab and the walls. In extremal...
  6. jb66

    Taipei 101

    I think that engineers are not sportsmen and engineering is not sportground. It means - to own some record in this branch is very good but it musn´t be the first impulse I want to achieve. Maybe I´m too much conservative but I´m sure that the first should be to design the construction which is...
  7. jb66

    Corrosion of concrete piles

    Ron, thank you very much for your helpfull advise. At first time I´ve seen the chemistry I verified the values of acidity, hardness and dissolved gases but all were confirmed again. It seemed to be incompatibility between acidity (weakly acid) and rather high content of CO2. I´m not chemist I...
  8. jb66

    Corrosion of pile

    Does anybody know if is it necessary to use secondary protection of concrete for piles in underground water which contens 83 mg/l CO2 aggressive(0,0083% per weight unit)or if is it possible to take only resistant basic material (concrete)? Water is acid (6,1 pH) and very hard. Thanks.
  9. jb66

    Corrosion of concrete piles

    I thing chemistry is OK, water is acid (6,1 pH), very hard and contens CO2 - I´m not sure if we use similar units - 83 mg/l in european units means 0,0083% CO2 per weight unit. Regards jb66
  10. jb66

    Corrosion of concrete piles

    Does anybody know if is it necessary to use secondary protection of concrete for piles in underground water which contens 83 mg/l CO2 aggressive or if is it possible to take only resistant basic material (concrete)? Thanks.
  11. jb66

    Corrosion of concrete piles

    Does anybody know if is it necessary to use secondary protection of concrete for piles in underground water which contens 83 mg/l CO2 aggressive or if is it possible to take only resistant basic material (concrete)? Thanks.
  12. jb66

    Dynamic module Es,dyn

    Thanks to AlohaBob, you are right of course but I´d like to know how can I calculate Es, dyn or how can I determine its value. Do you know?
  13. jb66

    Dynamic module Es,dyn

    Does anyone know something about dynamic module Es,dyn used for design of footing of wind energy plant? I´d like to know what is relation between Es, stat and Es,dyn. Thanks.
  14. jb66

    Dynamic modulus Es, dyn

    Anyone have any information about dynamic modulus Es,dyn used for design of footing of wind energy plant? I´d like to know what is relation between Es, stat and Es,dyn. Thanks.
  15. jb66

    Dynamic modulus Es, dyn

    Anyone have any information about dynamic modulus Es,dyn used for design of footing of wind energy plant? I´d like to know what is relation between Es, stat and Es,dyn. Thanks.