Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: zenom
  • Order by date
  1. zenom

    IBC Section 2305.3.7.2.1, Item 2. allowable shear of 490plf?

    It's open to interpretation. Ask you building official. The limits were placed there by committee members who don't like the "perforated" shear walls and a 490 plf design shear wall is the highest that was tested in the US, so that's the basis for that limit. There is no data to suggest the...
  2. zenom

    Wood shear wall / diaphram capacities

    The 25% adjustment and 40% account for different things. The shear wall and diaphragm table are based on principles of mechanics, see APA Research Reports 154 and 138. Basically a single fastener value, Z, is multiplied by load duration factor (1.6), diaphragm factor (1.1), number of nails per...