  1. dawn836

    ACI Code : Analysis

    well thanks all for your valueable replies, i have been discusing this issue with some engineer today, but there is a point i wonder about. what kind of analysis can i do to account for cracked sections instead of using modification factors directtly?
  2. dawn836

    Limiting Foundation Width

    well i have been discusing it with the geotechnical engineer who made the report he told me the only reason is to limit to 25 mm because depth of borehole was only 10 Ms here is another point what if i used isolated footing following his regulations and i have maximum width of it to be 3 Ms...
  3. dawn836

    Tempreature effect on steel truss

    Hi all I have a hall formed of steel N truss with upper and lower cord curved with same radiuses (parallel to each other) the expected variation in temperature between outside of the hall and inside is 35C the truss spans 30 Ms. I would like to include temperature gradient effect. Should it...
  4. dawn836

    Limiting Foundation Width

    well we received today 2 soil reports for other sites from same laboratory he gave also same recommendations for other different sites in different areas B.C. was different in each report but same recommendation for foundation width!! Depth of borehole was 10 Ms in the three reports, I wonder if...
  5. dawn836

    Limiting Foundation Width

    Thanks all for quick reply but considering the point of deflection, I made analysis using finite element analysis modeling footing as a shell and the soil foundation interaction as springs with modulus of subgrade reaction equals bearing capacity/settlement used for B.C. calculation, actually...
  6. dawn836

    Limiting Foundation Width

    Hi all I am a structural engineer with I think satisfactory understanding of soil mechanics , I got soil report for geotechnical engineer for design of a foundation , there was a note in the report stating that Isolated footings or strip footings shall be used with maximum width 3 Ms. Just I...
  7. dawn836

    ViewPort

    thanks CarlB and thanks all
  8. dawn836

    ViewPort

    Hi all i got a file from someone and i am supposed to make some modifications on, when i open layout and open the viewport autocad make zoom extend for view so how can i stop autocad from making Zoom Extend when i enter the view. i use Autocad 2006
  9. dawn836

    Scaling Factor for Response Spectrum

    Well Murali check clause number 1631.5.4 it tells that you must scale reponse spectrum Parametes(shear and moments and displacments) with Factor equals to Base Shear calculated from Response Spectrum Analysis divided by Base Shear obtained from Eaerth quick Analysis as per caluse 1630.2 For...
  10. dawn836

    Scaling Factor for Response Spectrum

    it should be the gravity acceleration depedning on units which yu use in modeling
  11. dawn836

    UBC 97 Orthognal Effects

    well thanks so much EBF i checked UBC97 again and found the following defination for Orthognal effects. ORTHOGONAL EFFECTS are the earthquake load effects on structural elements common to the lateral-force-resisting systems along two orthogonal axes. and the code does not mention anything...
  12. dawn836

    RESPONSE SPECTRUM ANALYSIS WITH ETABS

    well i would also to add my comment according to UBC97 here is statement from UBC97 1631.5.1 Response spectrum representation and interpretation of results. The ground motion representation shall be in accordance with Section 1631.2. The corresponding response parameters, including forces...
  13. dawn836

    UBC 97 Orthognal Effects

    well Thanks so much EBF another question, should i consider Orthognal effects when i am using either Equivalent Static Load Method or Response Spectrum Analysis?
  14. dawn836

    UBC97 Orthognal Effects

    When the requirment of orthognal effects shall be considered in the analysis of a building as stated in UBC 97(Section 1633)?
  15. dawn836

    UBC 97 Orthognal Effects

    Hi all When the requirment of orthognal effects shall be considered in the analysis of a building as stated in UBC 97(Section 1633)?
  16. dawn836

    "#value" error

    Hi all How can i make a cell empty instead of returning #value
  17. dawn836

    K value of side-sway columns

    well that article is perfect but i do not understand a phrase in this article "However, frame buckling capacity can be determined if the second-order analysis is taken incrementally to the limit." what incrementally to the limit mean?
  18. dawn836

    Pre-cambering of concrete beam

    Murali27 What is the yield strenght of steel(Fy) and the concrete cubic strenght (Fcu)?
  19. dawn836

    Response spectrum declaration

    you should declare two functions, every direction must has its one function with its own scale factor you may have force apllied in two directions in same function if you have to consider orthognal effects
  20. dawn836

    Buckling Lenght Factor

    well Jike Fe is function of lenght of member and buckling lenght factor(k) and also raduis of gryation(r), so how can this table be general for any section case?